Skip to main content
Window · Vinyl Frame NFRC ADC · Product Line ADC-K-27 ENERGY STAR Most Efficient Eligible

Advanced Window Corp. — 5300 Double Hung · Double Hung

Positioning #671/1,352 in certified Window, Advanced Window Corp. 5300 Double Hung pairs Vinyl frame construction with 647 glazing options rated between 0.15 and 0.47 SHGC across Northern, North-Central, South-Central, Southern. Across 16 certified Advanced Window Corp. product families, its thermal resistance spans 0.20 to 0.28 U-Factor and the line includes 78 ENERGY STAR Most Efficient packages (12.1% of line).

Min U-Factor
0.20
SHGC Range
0.15-0.47
Certified Options
647
Category Standing
#671 of 1,352

How does Advanced Window Corp. 5300 Double Hung compare thermally against Window peers?

Advanced Window Corp. 5300 Double Hung achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 5300 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 5300 Double Hung (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

5300 Double Hung Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Advanced Window Corp. 5300 Double Hung standing at #671 of 1,352 certified Window product series, tied with 70 others at 0.20, more insulating than 45.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.01 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 78 configurations meet ENERGY STAR Most Efficient criteria while 114 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-06-13 and cert timestamp 2024-01-19.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 647 certified glazing combinations for 5300 Double Hung (NFRC ADC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 114 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 450 packages (8 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 457 packages (8 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 457 packages (78 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Advanced Window Corp. produce?

Compare other active Advanced Window Corp. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advanced Window Corp. 5300 Double Hung appear below.

What U-Factor and SHGC range does Advanced Window Corp. 5300 Double Hung achieve?

Across 647 tested NFRC glazing configurations, Advanced Window Corp. 5300 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.20 minimum U-Factor and 0.15-0.47 SHGC band. It places #671 among 1,352 Window series—more insulating than 45.2%.

Which glazing options in Advanced Window Corp. 5300 Double Hung meet Northern climate limits?

Cold-climate buyers get 114 compliant Northern packages inside 5300 Double Hung, reaching down to U 0.20. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How do you calculate winter heat conduction for Advanced Window Corp. 5300 Double Hung?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make 5300 Double Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 5300 Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does 5300 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 457 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Advanced Window Corp. 5300 Double Hung, while total line SHGC reaches 0.47 in colder packages.

What glazing share inside 5300 Double Hung qualifies as Most Efficient?

No. Exactly 78 of 647 configurations (12.1%) earn ENERGY STAR Most Efficient status in 5300 Double Hung; the remaining standard v7.0 options pass base zone limits only.

Do 2026 5300 Double Hung installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Advanced Window Corp. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 5300 Double Hung glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.20-0.28, SHGC 0.15-0.47) against permit drawings for line ADC-K-27. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Advanced Window Corp. 5300 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros