Skip to main content
Window · Vinyl Frame NFRC AMS · Product Line AMS-A-56

Amsco Windows — VS1 (Studio) Single Hung · Single Hung

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Amsco Windows VS1 (Studio) Single Hung spans 1,038 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AMS, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.13 and 0.49.

Min U-Factor
0.25
SHGC Range
0.13-0.49
Certified Options
1,038
Category Standing
#1,174 of 1,352

How does Amsco Windows VS1 (Studio) Single Hung compare thermally against Window peers?

Amsco Windows VS1 (Studio) Single Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. VS1 (Studio) Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing VS1 (Studio) Single Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

VS1 (Studio) Single Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), VS1 (Studio) Single Hung is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.25-0.32.

Climate coverage for Amsco Windows VS1 (Studio) Single Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 18 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-10-08 licensing and 2024-01-22 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,038 certified glazing combinations for VS1 (Studio) Single Hung (NFRC AMS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 18 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 132 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 384 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 975 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Amsco Windows produce?

Compare other active Amsco Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Amsco Windows VS1 (Studio) Single Hung appear below.

What thermal performance numbers separate Amsco Windows VS1 (Studio) Single Hung from peers?

Testing puts Amsco Windows VS1 (Studio) Single Hung at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 1,038 configurations. Solar heat gain ranges between 0.13 and 0.49 across Northern, North-Central, South-Central, Southern.

How does Amsco Windows VS1 (Studio) Single Hung satisfy Version 7.0 Northern criteria?

With a 0.25 minimum U-Factor, Amsco Windows VS1 (Studio) Single Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 18 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How much winter heat loss does VS1 (Studio) Single Hung conduct across a 15 sq ft opening?

At U 0.25, a standard 3x5 ft (15 sq ft) VS1 (Studio) Single Hung opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

What homeowner profiles are a poor match for Amsco Windows VS1 (Studio) Single Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on VS1 (Studio) Single Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many VS1 (Studio) Single Hung glazing packages pass Southern solar-heat rules?

Yes, VS1 (Studio) Single Hung holds 975 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

How many Amsco Windows VS1 (Studio) Single Hung variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 1,038 VS1 (Studio) Single Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect VS1 (Studio) Single Hung?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 VS1 (Studio) Single Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Amsco Windows VS1 (Studio) Single Hung units match permits?

Match the NFRC thermal sticker for code AMS and line AMS-A-56 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Amsco Windows VS1 (Studio) Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros