Skip to main content
Window · Vinyl Frame NFRC YKK · Product Line YKK-A-3

YKK AP America, Inc. — Style View/Style View NT/Precedence/Style View Classic Single Hung · Single Hung

Across 9 YKK AP America, Inc. certified families, Style View/Style View NT/Precedence/Style View Classic Single Hung supplies 947 Single Hung configurations starting at 0.25 U-Factor and 0.18 SHGC for North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.26 SHGC. Its thermal floor ranks #1,174 of 1,352 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.18-0.26
Certified Options
947
Category Standing
#1,174 of 1,352

How does YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung compare thermally against Window peers?

YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Style View/Style View NT/Precedence/Style View Classic Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Style View/Style View NT/Precedence/Style View Classic Single Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Style View/Style View NT/Precedence/Style View Classic Single Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Style View/Style View NT/Precedence/Style View Classic Single Hung spans 947 NFRC test records (YKK), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Data provenance links certification 2024-02-21 and FENSTAR license 2019-01-31 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 947 certified glazing combinations for Style View/Style View NT/Precedence/Style View Classic Single Hung (NFRC YKK) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 36 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 303 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 947 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does YKK AP America, Inc. produce?

Compare other active YKK AP America, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung appear below.

How efficient is YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 947 configurations for YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung covering North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung qualify for the ENERGY STAR Northern Zone?

No. Because Style View/Style View NT/Precedence/Style View Classic Single Hung reaches only 0.25 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

How much winter heat loss does Style View/Style View NT/Precedence/Style View Classic Single Hung conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Style View/Style View NT/Precedence/Style View Classic Single Hung's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Which situations make Style View/Style View NT/Precedence/Style View Classic Single Hung the wrong window or door choice?

Do not specify Style View/Style View NT/Precedence/Style View Classic Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Style View/Style View NT/Precedence/Style View Classic Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does Style View/Style View NT/Precedence/Style View Classic Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 947 Southern-approved options within Style View/Style View NT/Precedence/Style View Classic Single Hung spanning SHGC down to 0.18. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 947 Style View/Style View NT/Precedence/Style View Classic Single Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to Style View/Style View NT/Precedence/Style View Classic Single Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 YKK AP America, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on Style View/Style View NT/Precedence/Style View Classic Single Hung?

Confirm both the paper NFRC label and permanent corner glass etch match line YKK-A-3 and NFRC ID YKK before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for YKK AP America, Inc. Style View/Style View NT/Precedence/Style View Classic Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros