Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-539

JELD-WEN, inc. — Brickmould Vinyl (V-3700) Horizontal Slider · Single Slider

JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider is a Single Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.25 across 782 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.13 to 0.49.

Min U-Factor
0.25
SHGC Range
0.13-0.49
Certified Options
782
Category Standing
#1,174 of 1,352

How does JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider compare thermally against Window peers?

JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Brickmould Vinyl (V-3700) Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Brickmould Vinyl (V-3700) Horizontal Slider (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Brickmould Vinyl (V-3700) Horizontal Slider Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Brickmould Vinyl (V-3700) Horizontal Slider spans 782 NFRC test records (JEL), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 26 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-09-19 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 782 certified glazing combinations for Brickmould Vinyl (V-3700) Horizontal Slider (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 26 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 52 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 100 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 730 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider appear below.

How efficient is JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider compared with peer Window models?

EPA ENERGY STAR v7.0 records 782 configurations for JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider qualify for the ENERGY STAR Northern Zone?

Because Brickmould Vinyl (V-3700) Horizontal Slider starts at 0.25 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 26 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How do you calculate winter heat conduction for JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Brickmould Vinyl (V-3700) Horizontal Slider's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What homeowner profiles are a poor match for JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Brickmould Vinyl (V-3700) Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Brickmould Vinyl (V-3700) Horizontal Slider?

Yes, Brickmould Vinyl (V-3700) Horizontal Slider holds 730 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

How many JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 782 Brickmould Vinyl (V-3700) Horizontal Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to Brickmould Vinyl (V-3700) Horizontal Slider?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 JELD-WEN, inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line JEL-A-539 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Brickmould Vinyl (V-3700) Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros