Door · Fiberglass Frame NFRC GWD · Product Line GWD-M-35 ENERGY STAR Most Efficient Eligible

Gilkey Window Company — 5000 Series Fiberglass Sliding Patio Door · Sliding Patio Door

Gilkey Window Company engineered the 5000 Series Fiberglass Sliding Patio Door Sliding Patio Door line for Northern, North-Central, South-Central, Southern, certifying 23 glass-spacer combinations from 0.17 to 0.28 U-Factor and 0.07 to 0.25 SHGC. Relative to other Fiberglass models tracked under NFRC GWD, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.07-0.25
Certified Options
23
Category Standing
#55 of 268

How does Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door compare thermally against Door peers?

Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 5000 Series Fiberglass Sliding Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 5000 Series Fiberglass Sliding Patio Door (U 0.17).28<=0.15650.16-0.18This model: U 0.17510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

5000 Series Fiberglass Sliding Patio Door Cohort StandingMin U-Factor 0.17 stands at rank #55 of 268, outperforming 72.4% of peers.Min U-Factor 0.17Rank #55 of 268 (72.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 5000 Series Fiberglass Sliding Patio Door spans 23 NFRC test records (GWD), ranking #55 of 268 Door families (tied with 19 others at 0.17, more insulating than 72.4% of Door lines, top 27.6%). Its 0.17 thermal floor compares at -0.02 against the Fiberglass median (0.19).

Mapping NFRC SHGC values (0.07 to 0.25) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 12 configurations meet ENERGY STAR Most Efficient criteria while 16 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-02-27.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 23 certified glazing combinations for 5000 Series Fiberglass Sliding Patio Door (NFRC GWD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 16 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 16 packages (12 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 22 packages (12 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 22 packages (12 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Modern MultiSlide Door Fiberglass 0.17 0.11 802
Foshan Xiaoluban Doors and Windows Co., Ltd. — XLB-80 Tilt Sliding Glass Door Aluminum 0.17 0.16 6
ProVia LLC — S-7500 Patio Door Vinyl 0.17 0.13 164
Lepage Millwork — Lift & Slide Door Other / Wood 0.17 0.12 165
OrePac Building Products — Steel Entry Door Wood 0.17 0.00 226

What other certified series does Gilkey Window Company produce?

Compare other active Gilkey Window Company certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door appear below.

How well does 5000 Series Fiberglass Sliding Patio Door by Gilkey Window Company insulate relative to Door benchmarks?

Built with Fiberglass framing in Sliding Glass Door (DDSG) style, Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door offers 23 Version 7.0 configurations from U 0.17 up to 0.28, posting -0.04 against the Door median of 0.21 with 12 Most Efficient picks.

Which glazing options in Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door meet Northern climate limits?

Prescriptive Northern compliance covers 16 5000 Series Fiberglass Sliding Patio Door packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates 5000 Series Fiberglass Sliding Patio Door from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on 5000 Series Fiberglass Sliding Patio Door's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

When should a buyer skip Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door and compare alternatives?

Skip 5000 Series Fiberglass Sliding Patio Door if local historic preservation boards prohibit Fiberglass profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 5000 Series Fiberglass Sliding Patio Door options exceeding U 0.22.

Does 5000 Series Fiberglass Sliding Patio Door meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 22 Southern-approved options within 5000 Series Fiberglass Sliding Patio Door spanning SHGC down to 0.07. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 5000 Series Fiberglass Sliding Patio Door qualifies as Most Efficient?

Only 12 options out of 23 (52.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 5000 Series Fiberglass Sliding Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 5000 Series Fiberglass Sliding Patio Door after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line GWD-M-35 and NFRC ID GWD before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Gilkey Window Company 5000 Series Fiberglass Sliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros