Skip to main content
Door · Fiberglass Frame NFRC MAR · Product Line MAR-N-445 ENERGY STAR Most Efficient Eligible

Marvin — Modern MultiSlide Door · Sliding Patio Door

Positioning #55/268 in certified Door, Marvin Modern MultiSlide Door pairs Fiberglass frame construction with 802 glazing options rated between 0.11 and 0.40 SHGC across Northern, North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.17 to 0.28 U-Factor and the line includes 138 ENERGY STAR Most Efficient packages (17.2% of line).

Min U-Factor
0.17
SHGC Range
0.11-0.40
Certified Options
802
Category Standing
#55 of 268

How does Marvin Modern MultiSlide Door compare thermally against Door peers?

Marvin Modern MultiSlide Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Modern MultiSlide DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Modern MultiSlide Door (U 0.17).28<=0.15650.16-0.18This model: U 0.17510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Modern MultiSlide Door Cohort StandingMin U-Factor 0.17 stands at rank #55 of 268, outperforming 72.4% of peers.Min U-Factor 0.17Rank #55 of 268 (72.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Modern MultiSlide Door spans 802 NFRC test records (MAR), ranking #55 of 268 Door families (tied with 19 others at 0.17, more insulating than 72.4% of Door lines, top 27.6%). Its 0.17 thermal floor compares at -0.02 against the Fiberglass median (0.19).

Mapping NFRC SHGC values (0.11 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 138 configurations meet ENERGY STAR Most Efficient criteria while 568 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-03-05 licensing and 2024-04-24 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 802 certified glazing combinations for Modern MultiSlide Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 568 packages (52 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 568 packages (112 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 549 packages (64 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 549 packages (90 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Modern MultiSlide Door appear below.

How efficient is Marvin Modern MultiSlide Door compared with peer Door models?

Testing puts Marvin Modern MultiSlide Door at rank #55 of 268 Door entries with U 0.17 to 0.28 across 802 configurations. Solar heat gain ranges between 0.11 and 0.40 across Northern, North-Central, South-Central, Southern.

Is Modern MultiSlide Door approved for Northern Zone heating climates?

Yes, 568 packages satisfy Northern ENERGY STAR Version 7.0 rules in Modern MultiSlide Door. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does Modern MultiSlide Door conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on Modern MultiSlide Door's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

Which situations make Modern MultiSlide Door the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Modern MultiSlide Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many Modern MultiSlide Door glazing packages pass Southern solar-heat rules?

Exactly 549 Modern MultiSlide Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.40 glass.

How many Marvin Modern MultiSlide Door variants earn ENERGY STAR Most Efficient?

EPA lists 138 Most Efficient options (17.2% share) inside Marvin Modern MultiSlide Door, out of 802 total Version 7.0 entries.

What federal compliance checks govern 2026 Modern MultiSlide Door window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify Modern MultiSlide Door glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-445, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Modern MultiSlide Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros