Skip to main content
Door · Aluminum Frame NFRC FXC · Product Line FXC-M-6 ENERGY STAR Most Efficient Eligible

Foshan Xiaoluban Doors and Windows Co., Ltd. — XLB-80 Tilt Sliding Glass Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 6 variants inside Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door, combining Aluminum frame construction with U-Factors spanning 0.17 to 0.28 and SHGC 0.16 to 0.26. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #55 of 268 among 268 Door families and posts 0.06 Btu/hr·ft²·°F more insulating than the 0.23 Btu/hr·ft²·°F median among Aluminum peers.

Min U-Factor
0.17
SHGC Range
0.16-0.26
Certified Options
6
Category Standing
#55 of 268

How does Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door compare thermally against Door peers?

Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. XLB-80 Tilt Sliding Glass DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing XLB-80 Tilt Sliding Glass Door (U 0.17).28<=0.15650.16-0.18This model: U 0.17510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

XLB-80 Tilt Sliding Glass Door Cohort StandingMin U-Factor 0.17 stands at rank #55 of 268, outperforming 72.4% of peers.Min U-Factor 0.17Rank #55 of 268 (72.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Aluminum cohort (0.23 median U-Factor), XLB-80 Tilt Sliding Glass Door reaches 0.17 on its lowest-conductivity package — #9 of 64 in Aluminum, tied with 2 others at 0.17, more insulating than 82.8% of Aluminum lines, top 17.2% (-0.06 vs Aluminum peers). Pairing NFRC ID FXC across multi-pane fills shifts U-Factor from 0.28 down toward 0.17.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 4 configurations meet ENERGY STAR Most Efficient criteria while 5 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2025-03-13 and cert timestamp 2026-04-02.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6 certified glazing combinations for XLB-80 Tilt Sliding Glass Door (NFRC FXC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 5 packages (1 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 5 packages (4 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 5 packages (3 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5 packages (3 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Gilkey Window Company — 5000 Series Fiberglass Sliding Patio Door Fiberglass 0.17 0.07 23
ProVia LLC — S-7500 Patio Door Vinyl 0.17 0.13 164
Lepage Millwork — Lift & Slide Door Other / Wood 0.17 0.12 165
OrePac Building Products — Steel Entry Door Wood 0.17 0.00 226
OrePac Building Products — Fiberglass Entry Door Wood 0.17 0.00 230

What other certified series does Foshan Xiaoluban Doors and Windows Co., Ltd. produce?

Compare other active Foshan Xiaoluban Doors and Windows Co., Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door appear below.

How efficient is Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door compared with peer Door models?

Built with Aluminum framing in Sliding Glass Door (DDSG) style, Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door offers 6 Version 7.0 configurations from U 0.17 up to 0.28, posting -0.04 against the Door median of 0.21 with 4 Most Efficient picks.

How does Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door satisfy Version 7.0 Northern criteria?

Yes, 5 packages satisfy Northern ENERGY STAR Version 7.0 rules in XLB-80 Tilt Sliding Glass Door. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), XLB-80 Tilt Sliding Glass Door at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make XLB-80 Tilt Sliding Glass Door the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on XLB-80 Tilt Sliding Glass Door options exceeding U 0.22. Additionally, do not order Sliding Glass Door (DDSG) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many XLB-80 Tilt Sliding Glass Door glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 5 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door, while total line SHGC reaches 0.26 in colder packages.

What glazing share inside XLB-80 Tilt Sliding Glass Door qualifies as Most Efficient?

Within XLB-80 Tilt Sliding Glass Door, 66.7% (4 of 6) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect XLB-80 Tilt Sliding Glass Door?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify XLB-80 Tilt Sliding Glass Door glass specs on job sites?

Verify NFRC ID FXC and series FXC-M-6 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Tilt Sliding Glass Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros