Skip to main content
Window · Aluminum Frame NFRC FXC · Product Line FXC-M-4 ENERGY STAR Most Efficient Eligible

Foshan Xiaoluban Doors and Windows Co., Ltd. — XLB-80 Fixed Window · Picture Window

Across 7 Foshan Xiaoluban Doors and Windows Co., Ltd. certified families, XLB-80 Fixed Window supplies 7 Picture Window configurations starting at 0.15 U-Factor and 0.17 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.30 U-Factor and 0.27 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.15
SHGC Range
0.17-0.27
Certified Options
7
Category Standing
#136 of 1,352

How does Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window compare thermally against Window peers?

Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. XLB-80 Fixed WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing XLB-80 Fixed Window (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

XLB-80 Fixed Window Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.27 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 5 configurations meet ENERGY STAR Most Efficient criteria while 5 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2025-03-13 licensing and 2026-04-02 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7 certified glazing combinations for XLB-80 Fixed Window (NFRC FXC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 5 packages (2 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 5 packages (4 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 5 packages (3 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 6 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
DRUTEX S.A. — MB-79N/MB-86N SI Fixed Window Aluminum 0.15 0.04 2,540
Quaker Window Products — H4503 Fixed Picture Window Aluminum 0.15 0.14 3,262
Quaker Window Products — C600/C300 Fixed Aluminum 0.15 0.13 4,805
JELD-WEN, inc. — 8500 Hybrid Casement Aluminum 0.15 0.13 60,304
Kohltech International, Ltd. — S-100 Sidelite Vinyl / Wood 0.15 0.23 20

What other certified series does Foshan Xiaoluban Doors and Windows Co., Ltd. produce?

Compare other active Foshan Xiaoluban Doors and Windows Co., Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window appear below.

What U-Factor and SHGC range does Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window achieve?

Testing puts Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window at rank #136 of 1,352 Window entries with U 0.15 to 0.30 across 7 configurations. Solar heat gain ranges between 0.17 and 0.27 across Northern, North-Central, South-Central, Southern.

How does Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 5 XLB-80 Fixed Window packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.30, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates XLB-80 Fixed Window from the 0.22 Northern rule?

Using NFRC FXC U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

Which situations make XLB-80 Fixed Window the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on XLB-80 Fixed Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many XLB-80 Fixed Window glazing packages pass Southern solar-heat rules?

Yes. 6 Southern-certified options inside Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.27 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window variants earn ENERGY STAR Most Efficient?

Within XLB-80 Fixed Window, 71.4% (5 of 7) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect XLB-80 Fixed Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 XLB-80 Fixed Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window units match permits?

Inspectors match the temporary NFRC sticker (U 0.15-0.30, SHGC 0.17-0.27) against permit drawings for line FXC-M-4. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)