Window · Vinyl / Wood Frame NFRC KOI · Product Line KOI-A-33

Kohltech International, Ltd. — S-100 Sidelite · Sidelite

Across 21 Kohltech International, Ltd. certified families, S-100 Sidelite supplies 20 Sidelite configurations starting at 0.15 U-Factor and 0.23 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.24 U-Factor and 0.32 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.15
SHGC Range
0.23-0.32
Certified Options
20
Category Standing
#136 of 1,352

How does Kohltech International, Ltd. S-100 Sidelite compare thermally against Window peers?

Kohltech International, Ltd. S-100 Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. S-100 SideliteHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing S-100 Sidelite (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

S-100 Sidelite Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across S-100 Sidelite spans 20 NFRC test records (KOI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at +0.01 against the Vinyl / Wood median (0.14).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 20 combinations qualify in the Northern Zone alongside 2 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Lifecycle documentation anchors KOI to 2025-02-10 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 20 certified glazing combinations for S-100 Sidelite (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 20 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 20 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. S-100 Sidelite appear below.

How well does S-100 Sidelite by Kohltech International, Ltd. insulate relative to Window benchmarks?

Across 20 tested NFRC glazing configurations, Kohltech International, Ltd. S-100 Sidelite with Vinyl / Wood framing and Fixed Sidelite (FXSL) style reaches a 0.15 minimum U-Factor and 0.23-0.32 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

Which glazing options in Kohltech International, Ltd. S-100 Sidelite meet Northern climate limits?

Yes, 20 packages satisfy Northern ENERGY STAR Version 7.0 rules in S-100 Sidelite. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does S-100 Sidelite conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), S-100 Sidelite at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make S-100 Sidelite the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S-100 Sidelite options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is S-100 Sidelite suitable for sunbelt cooling-dominated homes?

Yes, S-100 Sidelite holds 2 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.23 SHGC in cooling climates.

What glazing share inside S-100 Sidelite qualifies as Most Efficient?

No. Zero of the 20 configurations in Kohltech International, Ltd. S-100 Sidelite hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect S-100 Sidelite?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current S-100 Sidelite retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify S-100 Sidelite glass specs on job sites?

Match the NFRC thermal sticker for code KOI and line KOI-A-33 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. S-100 Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)