Foshan Xiaoluban Doors and Windows Co., Ltd. — XLB-80 Casement Window · Casement Windows
Positioning #936/1,352 in certified Window, Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window pairs Aluminum frame construction with 8 glazing options rated between 0.11 and 0.20 SHGC across North-Central, South-Central, Southern. Across 7 certified Foshan Xiaoluban Doors and Windows Co., Ltd. product families, its thermal resistance spans 0.23 to 0.31 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.
- Min U-Factor
- 0.23
- SHGC Range
- 0.11-0.20
- Certified Options
- 8
- Category Standing
- #936 of 1,352
How does Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window compare thermally against Window peers?
Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across XLB-80 Casement Window spans 8 NFRC test records (FXC), ranking #936 of 1,352 Window families (tied with 97 others at 0.23, more insulating than 23.6% of Window lines). Its 0.23 thermal floor compares at At median against the Aluminum median (0.23).
Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.
Data provenance links certification 2026-04-02 and FENSTAR license 2025-03-13 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 8 certified glazing combinations for XLB-80 Casement Window (NFRC FXC) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 4 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 5 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 8 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| KP Building Products Limited — 2100/6500 Casement, 2120/6520 Fixed Casement | Vinyl | 0.23 | 0.18 | 8 |
| KP Building Products Limited — 3020/3520 Fixed Window | Vinyl | 0.23 | 0.20 | 8 |
| KP Building Products Limited — 2110/6510 Awning | Vinyl | 0.23 | 0.18 | 4 |
| Taylors Window and Screen, Inc. — 8501 NC/Repl Casement Picture Window | Vinyl | 0.23 | 0.18 | 18 |
| Morfe Windows LLC — Horizontal Sliding Window | Vinyl | 0.23 | 0.18 | 20 |
What other certified series does Foshan Xiaoluban Doors and Windows Co., Ltd. produce?
Compare other active Foshan Xiaoluban Doors and Windows Co., Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
XLB-80 Tilt Sliding Glass Door
U-Factor 0.17–0.28 · 6 certified options.
XLB-80 Swinging Exterior Door
U-Factor 0.18–0.24 · 5 certified options.
XLB-80 Dual Action Window
U-Factor 0.20–0.29 · 10 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window appear below.
How efficient is Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window compared with peer Window models?
Testing puts Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window at rank #936 of 1,352 Window entries with U 0.23 to 0.31 across 8 configurations. Solar heat gain ranges between 0.11 and 0.20 across North-Central, South-Central, Southern.
Which glazing options in Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window meet Northern climate limits?
No. Because XLB-80 Casement Window reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Aluminum line strictly across North-Central, South-Central, Southern cooling or mixed markets.
How does a 3x5 ft XLB-80 Casement Window window perform under a 40 deg F temperature drop?
Using NFRC FXC U-Factor 0.23, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).
What homeowner profiles are a poor match for Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window?
Cold-climate owners needing prescriptive U <= 0.22 should pass on XLB-80 Casement Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
What Southern ENERGY STAR v7.0 options exist in XLB-80 Casement Window?
Yes. 8 Southern-certified options inside Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.20 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in XLB-80 Casement Window holds Most Efficient recognition?
Zero glazing builds inside XLB-80 Casement Window's 8 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
What 2026 federal tax credit and Lead RRP rules apply to XLB-80 Casement Window?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Foshan Xiaoluban Doors and Windows Co., Ltd. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
Where are NFRC and IGCC identification marks located on XLB-80 Casement Window?
Confirm both the paper NFRC label and permanent corner glass etch match line FXC-M-5 and NFRC ID FXC before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Foshan Xiaoluban Doors and Windows Co., Ltd. XLB-80 Casement Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)