OrePac Building Products — Fiberglass Entry Door · Swinging Entry Door (Single)

OrePac Building Products engineered the Fiberglass Entry Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 230 glass-spacer combinations from 0.17 to 0.28 U-Factor and 0.00 to 0.26 SHGC. Relative to other Wood models tracked under NFRC ORE, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.00-0.26
Certified Options
230
Category Standing
#55 of 268

How does OrePac Building Products Fiberglass Entry Door compare thermally against Door peers?

OrePac Building Products Fiberglass Entry Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Fiberglass Entry DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Fiberglass Entry Door (U 0.17).28<=0.15650.16-0.18This model: U 0.17510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Fiberglass Entry Door Cohort StandingMin U-Factor 0.17 stands at rank #55 of 268, outperforming 72.4% of peers.Min U-Factor 0.17Rank #55 of 268 (72.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Fiberglass Entry Door is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame with Fiberglass sash. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 189 combinations qualify in the Northern Zone alongside 229 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2024-11-22 and v7.0 data certification on 2025-01-23. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 230 certified glazing combinations for Fiberglass Entry Door (NFRC ORE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 189 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 189 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 229 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 229 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does OrePac Building Products produce?

Compare other active OrePac Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OrePac Building Products Fiberglass Entry Door appear below.

What thermal performance numbers separate OrePac Building Products Fiberglass Entry Door from peers?

EPA ENERGY STAR v7.0 records 230 configurations for OrePac Building Products Fiberglass Entry Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Is Fiberglass Entry Door approved for Northern Zone heating climates?

OrePac Building Products Fiberglass Entry Door supplies 189 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

How does a 3x5 ft Fiberglass Entry Door window perform under a 40 deg F temperature drop?

At U 0.17, a standard 3x5 ft (15 sq ft) Fiberglass Entry Door opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

What are the practical limitations of specifying Fiberglass Entry Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Fiberglass Entry Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install OrePac Building Products Fiberglass Entry Door in Southern or South-Central zones?

Warm-climate homeowners have 229 Southern-approved options within Fiberglass Entry Door spanning SHGC down to 0.00. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 230 Fiberglass Entry Door configurations ENERGY STAR Most Efficient?

Zero glazing builds inside Fiberglass Entry Door's 230 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Do 2026 Fiberglass Entry Door installations qualify for IRS Section 25C tax credits?

Any Fiberglass Entry Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC ORE and product line ORE-M-7 on delivery?

Inspectors match the temporary NFRC sticker (U 0.17-0.28, SHGC 0.00-0.26) against permit drawings for line ORE-M-7. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OrePac Building Products Fiberglass Entry Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros