Skip to main content
Door · Wood Frame NFRC MAR · Product Line MAR-N-477

Marvin — Ultimate Outswing French Door G2 · Swinging Entry Door (Double)

Marvin engineered the Ultimate Outswing French Door G2 Swinging Entry Door, Double line for Northern, North-Central, South-Central, Southern, certifying 56,123 glass-spacer combinations from 0.17 to 0.28 U-Factor and 0.07 to 0.39 SHGC. Relative to other Wood models tracked under NFRC MAR, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.07-0.39
Certified Options
56,123
Category Standing
#55 of 268

How does Marvin Ultimate Outswing French Door G2 compare thermally against Door peers?

Marvin Ultimate Outswing French Door G2 achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Ultimate Outswing French Door G2Histogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Ultimate Outswing French Door G2 (U 0.17).28<=0.15650.16-0.18This model: U 0.17510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Ultimate Outswing French Door G2 Cohort StandingMin U-Factor 0.17 stands at rank #55 of 268, outperforming 72.4% of peers.Min U-Factor 0.17Rank #55 of 268 (72.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultimate Outswing French Door G2 spans 56,123 NFRC test records (MAR), ranking #55 of 268 Door families (tied with 19 others at 0.17, more insulating than 72.4% of Door lines, top 27.6%). Its 0.17 thermal floor compares at -0.04 against the Wood median (0.21).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 20,210 combinations qualify in the Northern Zone alongside 53,973 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-06-17. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56,123 certified glazing combinations for Ultimate Outswing French Door G2 (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 20,210 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 20,210 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 53,973 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 53,973 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Outswing French Door G2 appear below.

How efficient is Marvin Ultimate Outswing French Door G2 compared with peer Door models?

Across 56,123 tested NFRC glazing configurations, Marvin Ultimate Outswing French Door G2 with Wood framing and Hinged Patio French Door (DDFR) style reaches a 0.17 minimum U-Factor and 0.07-0.39 SHGC band. It places #55 among 268 Door series—top 27.6%.

Which glazing options in Marvin Ultimate Outswing French Door G2 meet Northern climate limits?

Cold-climate buyers get 20,210 compliant Northern packages inside Ultimate Outswing French Door G2, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

What BTU/hr heat transfer results from Ultimate Outswing French Door G2's 0.17 minimum U-Factor?

Using NFRC MAR U-Factor 0.17, a 15 sq ft Hinged Patio French Door (DDFR) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

What homeowner profiles are a poor match for Marvin Ultimate Outswing French Door G2?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Outswing French Door G2 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does Ultimate Outswing French Door G2 meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Ultimate Outswing French Door G2 holds 53,973 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

How many Marvin Ultimate Outswing French Door G2 variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside Ultimate Outswing French Door G2's 56,123 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Marvin Ultimate Outswing French Door G2 in 2026?

Any Ultimate Outswing French Door G2 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Marvin Ultimate Outswing French Door G2 units match permits?

Match the NFRC thermal sticker for code MAR and line MAR-N-477 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Outswing French Door G2 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros