Kolbe and Kolbe Millwork Co., Inc — Ultra/VistaLuxe Inswing Entrance Door · Swinging Entry Door (Single)
Positioning #55/268 in certified Door, Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door pairs Wood frame construction with 3,719 glazing options rated between 0.04 and 0.37 SHGC across Northern, North-Central, South-Central, Southern. Across 57 certified Kolbe and Kolbe Millwork Co., Inc product families, its thermal resistance spans 0.17 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.
- Min U-Factor
- 0.17
- SHGC Range
- 0.04-0.37
- Certified Options
- 3,719
- Category Standing
- #55 of 268
How does Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door compare thermally against Door peers?
Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Ultra/VistaLuxe Inswing Entrance Door reaches 0.17 on its lowest-conductivity package — #88 of 408 in Wood, tied with 34 others at 0.17, more insulating than 70.1% of Wood lines, top 29.9% (-0.04 vs Wood peers). Pairing NFRC ID KKM across multi-pane fills shifts U-Factor from 0.28 down toward 0.17.
Mapping NFRC SHGC values (0.04 to 0.37) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 3,081 combinations qualify in the Northern Zone alongside 3,523 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2025-03-17.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 3,719 certified glazing combinations for Ultra/VistaLuxe Inswing Entrance Door (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 3,081 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 3,081 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 3,523 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 3,523 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Therma-Tru Corporation — Classic Craft Fiberglass Entry Door | Wood | 0.17 | 0.01 | 378 |
| OrePac Building Products — Fiberglass Entry Door | Wood | 0.17 | 0.00 | 230 |
| OrePac Building Products — Steel Entry Door | Wood | 0.17 | 0.00 | 226 |
| Marvin — Ultimate Inswing French Door G2 | Wood | 0.17 | 0.07 | 52,934 |
| Marvin — Ultimate Outswing French Door G2 | Wood | 0.17 | 0.07 | 56,123 |
What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?
Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Heritage Casement Picture Sash Set
U-Factor 0.11–0.31 · 1,234 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door appear below.
Where does Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door stand thermally among ENERGY STAR Door lines?
Built with Wood framing in Entry Door Single-Lite (EDSL) style, Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door offers 3,719 Version 7.0 configurations from U 0.17 up to 0.28, posting -0.04 against the Door median of 0.21 with 0 Most Efficient picks.
How does Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door satisfy Version 7.0 Northern criteria?
Prescriptive Northern compliance covers 3,081 Ultra/VistaLuxe Inswing Entrance Door packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.
What conductive BTU/hr difference separates Ultra/VistaLuxe Inswing Entrance Door from the 0.22 Northern rule?
At U 0.17, a standard 3x5 ft (15 sq ft) Ultra/VistaLuxe Inswing Entrance Door opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.
What homeowner profiles are a poor match for Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra/VistaLuxe Inswing Entrance Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door in Southern or South-Central zones?
Exactly 3,523 Ultra/VistaLuxe Inswing Entrance Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.04 rather than higher 0.37 glass.
What glazing share inside Ultra/VistaLuxe Inswing Entrance Door qualifies as Most Efficient?
No. Zero of the 3,719 configurations in Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
Do 2026 Ultra/VistaLuxe Inswing Entrance Door installations qualify for IRS Section 25C tax credits?
Any Ultra/VistaLuxe Inswing Entrance Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do you cross-check NFRC KKM and product line KKM-N-254 on delivery?
Inspectors match the temporary NFRC sticker (U 0.17-0.28, SHGC 0.04-0.37) against permit drawings for line KKM-N-254. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Inswing Entrance Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)