Skip to main content
Window · Wood Frame NFRC JEL · Product Line JEL-N-668

JELD-WEN, inc. — Custom Clad Casement · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 774 variants inside JELD-WEN, inc. Custom Clad Casement, combining Wood frame with Metal-Clad Wood sash with U-Factors spanning 0.23 to 0.32 and SHGC 0.11 to 0.40. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #936 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.23
SHGC Range
0.11-0.40
Certified Options
774
Category Standing
#936 of 1,352

How does JELD-WEN, inc. Custom Clad Casement compare thermally against Window peers?

JELD-WEN, inc. Custom Clad Casement achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Custom Clad CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Custom Clad Casement (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Custom Clad Casement Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Custom Clad Casement at rank #936 of 1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.40 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 8 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-18 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 774 certified glazing combinations for Custom Clad Casement (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 8 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 23 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 81 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 760 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Clad Casement appear below.

What U-Factor and SHGC range does JELD-WEN, inc. Custom Clad Casement achieve?

JELD-WEN, inc. Custom Clad Casement spans 774 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.11 to 0.40. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.

Is Custom Clad Casement approved for Northern Zone heating climates?

Northern qualification on Custom Clad Casement relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 8 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What conductive BTU/hr difference separates Custom Clad Casement from the 0.22 Northern rule?

Using NFRC JEL U-Factor 0.23, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

What are the practical limitations of specifying Custom Clad Casement?

Skip Custom Clad Casement if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Clad Casement options exceeding U 0.22.

Is Custom Clad Casement suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 760 Southern-approved options within Custom Clad Casement spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 774 Custom Clad Casement configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 774 Custom Clad Casement options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to Custom Clad Casement?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC JEL and product line JEL-N-668 on delivery?

Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.11-0.40) against permit drawings for line JEL-N-668. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Clad Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros