JELD-WEN, inc. — Custom Wood Epic Double Hung · Double Hung
JELD-WEN, inc. Custom Wood Epic Double Hung is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.23 across 622 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.36.
- Min U-Factor
- 0.23
- SHGC Range
- 0.09-0.36
- Certified Options
- 622
- Category Standing
- #936 of 1,352
How does JELD-WEN, inc. Custom Wood Epic Double Hung compare thermally against Window peers?
JELD-WEN, inc. Custom Wood Epic Double Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 61 certified JELD-WEN, inc. series, this Double Hung offers a 0.09 U-Factor adjustment span between 0.32 entry options and 0.23 top-performing glazing. Category standing is #936/1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines).
Mapping NFRC SHGC values (0.09 to 0.36) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors JEL to 2024-08-08 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 622 certified glazing combinations for Custom Wood Epic Double Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 1 package (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 24 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 147 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 618 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Legend Double Hung | Wood | 0.23 | 0.11 | 598 |
| Windsor Windows and Doors — Legend Double Hung Transom | Wood | 0.23 | 0.10 | 777 |
| Weather Shield Mfg., Inc. — 8116/1108/1109 DH Picture & 8117/1110/1111 DH Transom | Wood | 0.23 | 0.11 | 454 |
| Andersen Corporation — A-Series Frenchwood® Patio Door Sidelight | Wood | 0.23 | 0.10 | 799 |
| Weather Shield Mfg., Inc. — 8219 Casement | Wood | 0.23 | 0.11 | 273 |
What other certified series does JELD-WEN, inc. produce?
Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7500 Series Horizontal Slider
U-Factor 0.14–0.32 · 42,001 certified options.
Premium Vinyl (V-4500) Casement Fixed Direct Set
U-Factor 0.14–0.32 · 2,573 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Wood Epic Double Hung appear below.
How efficient is JELD-WEN, inc. Custom Wood Epic Double Hung compared with peer Window models?
Across 622 tested NFRC glazing configurations, JELD-WEN, inc. Custom Wood Epic Double Hung with Wood framing and Double-Hung (VSDH) style reaches a 0.23 minimum U-Factor and 0.09-0.36 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.
Can homeowners install Custom Wood Epic Double Hung in cold Northern ENERGY STAR counties?
Northern qualification on Custom Wood Epic Double Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 1 package pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How does a 3x5 ft Custom Wood Epic Double Hung window perform under a 40 deg F temperature drop?
Using NFRC JEL U-Factor 0.23, a 15 sq ft Double-Hung (VSDH) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).
When should a buyer skip JELD-WEN, inc. Custom Wood Epic Double Hung and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Wood Epic Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Does Custom Wood Epic Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?
Exactly 618 Custom Wood Epic Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.36 glass.
Does Custom Wood Epic Double Hung carry EPA Most Efficient certification across its lineup?
Zero glazing builds inside Custom Wood Epic Double Hung's 622 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
Do 2026 Custom Wood Epic Double Hung installations qualify for IRS Section 25C tax credits?
Any Custom Wood Epic Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do building inspectors verify Custom Wood Epic Double Hung glass specs on job sites?
Confirm both the paper NFRC label and permanent corner glass etch match line JEL-N-792 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Wood Epic Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)