Kolbe and Kolbe Millwork Co., Inc — Forgent Double Hung · Double Hung
Across 57 Kolbe and Kolbe Millwork Co., Inc certified families, Forgent Double Hung supplies 5,088 Double Hung configurations starting at 0.14 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.44 SHGC. Its thermal floor ranks #72 of 1,352 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.14
- SHGC Range
- 0.09-0.44
- Certified Options
- 5,088
- Category Standing
- #72 of 1,352
How does Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung compare thermally against Window peers?
Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl / Wood cohort (0.14 median U-Factor), Forgent Double Hung reaches 0.14 on its lowest-conductivity package — #5 of 16 in Vinyl / Wood, tied with 4 others at 0.14, more insulating than 43.8% of Vinyl / Wood lines (At median vs Vinyl / Wood peers). Pairing NFRC ID KKM across multi-pane fills shifts U-Factor from 0.32 down toward 0.14.
Climate coverage for Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 3,000 configurations meet ENERGY STAR Most Efficient criteria while 1,324 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-03-18 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 5,088 certified glazing combinations for Forgent Double Hung (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 1,324 packages (1,008 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 3,472 packages (2,992 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 3,544 packages (2,392 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 4,416 packages (2,392 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| MI Windows and Doors, LLC — SR CASE PW Vinyl Fixed Window | Vinyl | 0.14 | 0.08 | 5,254 |
| Weather Shield Mfg., Inc. — 630 Wood Direct Set | Wood | 0.14 | 0.13 | 5,555 |
| JELD-WEN, inc. — Siteline Clad Wood (W-5500) Fixed Direct Set Geo | Wood | 0.14 | 0.13 | 4,582 |
| Great Day Improvements, LLC — 8200 Plus Picture | Vinyl | 0.14 | 0.17 | 4,219 |
| Milgard Manufacturing, Inc. — 12710 Fixed | Vinyl | 0.14 | 0.10 | 3,568 |
What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?
Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Heritage Casement Picture Sash Set
U-Factor 0.11–0.31 · 1,234 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung appear below.
Where does Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung stand thermally among ENERGY STAR Window lines?
Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung spans 5,088 certified configurations with U-Factors between 0.14 and 0.32 and SHGC values from 0.09 to 0.44. Ranked #72 of 1,352 Window families, it carries 3,000 Most Efficient options.
Is Forgent Double Hung approved for Northern Zone heating climates?
Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung supplies 1,324 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.
What BTU/hr heat transfer results from Forgent Double Hung's 0.14 minimum U-Factor?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 84.0 BTU/hr on Forgent Double Hung's lowest-U package (0.14), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
What are the practical limitations of specifying Forgent Double Hung?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Forgent Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
What Southern ENERGY STAR v7.0 options exist in Forgent Double Hung?
Across Northern, North-Central, South-Central, Southern, 4,416 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung, while total line SHGC reaches 0.44 in colder packages.
Which package tier in Forgent Double Hung holds Most Efficient recognition?
Only 3,000 options out of 5,088 (59.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung, usually requiring triple-pane or upgraded Low-E coatings.
Can homeowners claim Form 5695 credits on Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How can homeowners confirm delivered Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line KKM-N-260 and NFRC ID KKM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Forgent Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)