KP Building Products Limited — 4000 Double Hung / 4030 Single Hung · Double Hung

Across 15 KP Building Products Limited certified families, 4000 Double Hung / 4030 Single Hung supplies 4 Double Hung configurations starting at 0.25 U-Factor and 0.19 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.26 U-Factor and 0.49 SHGC. Its thermal floor ranks #1,174 of 1,352 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.19-0.49
Certified Options
4
Category Standing
#1,174 of 1,352

How does KP Building Products Limited 4000 Double Hung / 4030 Single Hung compare thermally against Window peers?

KP Building Products Limited 4000 Double Hung / 4030 Single Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 4000 Double Hung / 4030 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 4000 Double Hung / 4030 Single Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

4000 Double Hung / 4030 Single Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 4000 Double Hung / 4030 Single Hung spans 4 NFRC test records (FAR), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-06-13 and v7.0 data certification on 2025-02-11. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for 4000 Double Hung / 4030 Single Hung (NFRC FAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 2 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does KP Building Products Limited produce?

Compare other active KP Building Products Limited certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to KP Building Products Limited 4000 Double Hung / 4030 Single Hung appear below.

What U-Factor and SHGC range does KP Building Products Limited 4000 Double Hung / 4030 Single Hung achieve?

Built with Vinyl framing in Double-Hung (VSDH) style, KP Building Products Limited 4000 Double Hung / 4030 Single Hung offers 4 Version 7.0 configurations from U 0.25 up to 0.26, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

How does KP Building Products Limited 4000 Double Hung / 4030 Single Hung satisfy Version 7.0 Northern criteria?

Prescriptive Northern approval ends at U <= 0.22, above 4000 Double Hung / 4030 Single Hung's 0.25 minimum. However, 2 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

What conductive BTU/hr difference separates 4000 Double Hung / 4030 Single Hung from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 4000 Double Hung / 4030 Single Hung at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 4000 Double Hung / 4030 Single Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 4000 Double Hung / 4030 Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Is 4000 Double Hung / 4030 Single Hung suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 2 Southern-approved options within 4000 Double Hung / 4030 Single Hung spanning SHGC down to 0.19. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 4000 Double Hung / 4030 Single Hung qualifies as Most Efficient?

Zero glazing builds inside 4000 Double Hung / 4030 Single Hung's 4 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

How do the 25C sunset and pre-1978 Lead RRP rules affect 4000 Double Hung / 4030 Single Hung?

Any 4000 Double Hung / 4030 Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC FAR and product line FAR-M-22 on delivery?

Match the NFRC thermal sticker for code FAR and line FAR-M-22 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for KP Building Products Limited 4000 Double Hung / 4030 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros