Skip to main content
Window · Vinyl Frame NFRC TWS · Product Line TWS-K-2

Taylors Window and Screen, Inc. — 7000/8000 Series Slider · Double Slider

Taylors Window and Screen, Inc. 7000/8000 Series Slider is a Double Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.25 across 12 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.17 to 0.26.

Min U-Factor
0.25
SHGC Range
0.17-0.26
Certified Options
12
Category Standing
#1,174 of 1,352

How does Taylors Window and Screen, Inc. 7000/8000 Series Slider compare thermally against Window peers?

Taylors Window and Screen, Inc. 7000/8000 Series Slider achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7000/8000 Series SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 7000/8000 Series Slider (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7000/8000 Series Slider Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 9 certified Taylors Window and Screen, Inc. series, this Double Slider offers a 0.03 U-Factor adjustment span between 0.28 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).

Climate coverage for Taylors Window and Screen, Inc. 7000/8000 Series Slider spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Data provenance links certification 2026-02-23 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12 certified glazing combinations for 7000/8000 Series Slider (NFRC TWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 8 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 8 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 8 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Taylors Window and Screen, Inc. produce?

Compare other active Taylors Window and Screen, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Taylors Window and Screen, Inc. 7000/8000 Series Slider appear below.

What U-Factor and SHGC range does Taylors Window and Screen, Inc. 7000/8000 Series Slider achieve?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Taylors Window and Screen, Inc. 7000/8000 Series Slider offers 12 Version 7.0 configurations from U 0.25 up to 0.28, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

Does Taylors Window and Screen, Inc. 7000/8000 Series Slider qualify for the ENERGY STAR Northern Zone?

Taylors Window and Screen, Inc. 7000/8000 Series Slider holds zero Northern Zone qualifications (min U 0.25). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

What conductive BTU/hr difference separates 7000/8000 Series Slider from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 7000/8000 Series Slider at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 7000/8000 Series Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 7000/8000 Series Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many 7000/8000 Series Slider glazing packages pass Southern solar-heat rules?

Across North-Central, South-Central, Southern, 8 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Taylors Window and Screen, Inc. 7000/8000 Series Slider, while total line SHGC reaches 0.26 in colder packages.

What glazing share inside 7000/8000 Series Slider qualifies as Most Efficient?

7000/8000 Series Slider holds zero Most Efficient entries across its 12 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What 2026 federal tax credit and Lead RRP rules apply to 7000/8000 Series Slider?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 7000/8000 Series Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify 7000/8000 Series Slider glass specs on job sites?

Match the NFRC thermal sticker for code TWS and line TWS-K-2 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Taylors Window and Screen, Inc. 7000/8000 Series Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros