KP Building Products Limited — 4200 Lift Out Slider · Double Slider
EPA ENERGY STAR Version 7.0 certifies 4 variants inside KP Building Products Limited 4200 Lift Out Slider, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.26 and SHGC 0.19 to 0.50. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #1,174 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.25
- SHGC Range
- 0.19-0.50
- Certified Options
- 4
- Category Standing
- #1,174 of 1,352
How does KP Building Products Limited 4200 Lift Out Slider compare thermally against Window peers?
KP Building Products Limited 4200 Lift Out Slider achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 15 certified KP Building Products Limited series, this Double Slider offers a 0.01 U-Factor adjustment span between 0.26 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-06-13 and cert timestamp 2025-02-11.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 4 certified glazing combinations for 4200 Lift Out Slider (NFRC FAR) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 2 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 2 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 2 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 2 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Walsh Building Products — #5600 Picture Window | Vinyl | 0.25 | 0.21 | 9 |
| Taylors Window and Screen, Inc. — 7000/8000 Series Double Hung | Vinyl | 0.25 | 0.17 | 12 |
| Taylors Window and Screen, Inc. — 7000/8000 Series Slider | Vinyl | 0.25 | 0.17 | 12 |
| St. Albans Window Mfg. — 200 Double Hung | Vinyl | 0.25 | 0.17 | 27 |
| St. Albans Window Mfg. — 200 Horizontal Slider | Vinyl | 0.25 | 0.16 | 32 |
What other certified series does KP Building Products Limited produce?
Compare other active KP Building Products Limited certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
2100/6500 Casement, 2120/6520 Fixed Casement
U-Factor 0.23–0.24 · 8 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to KP Building Products Limited 4200 Lift Out Slider appear below.
How efficient is KP Building Products Limited 4200 Lift Out Slider compared with peer Window models?
Testing puts KP Building Products Limited 4200 Lift Out Slider at rank #1,174 of 1,352 Window entries with U 0.25 to 0.26 across 4 configurations. Solar heat gain ranges between 0.19 and 0.50 across Northern, North-Central, South-Central, Southern.
How does KP Building Products Limited 4200 Lift Out Slider satisfy Version 7.0 Northern criteria?
Because 4200 Lift Out Slider starts at 0.25 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 2 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
What conductive BTU/hr difference separates 4200 Lift Out Slider from the 0.22 Northern rule?
Using NFRC FAR U-Factor 0.25, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).
Which situations make 4200 Lift Out Slider the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 4200 Lift Out Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Does 4200 Lift Out Slider meet Southern hot-climate SHGC caps (<= 0.23)?
Exactly 2 4200 Lift Out Slider options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.19 rather than higher 0.50 glass.
Does 4200 Lift Out Slider carry EPA Most Efficient certification across its lineup?
Zero glazing builds inside 4200 Lift Out Slider's 4 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
What 2026 federal tax credit and Lead RRP rules apply to 4200 Lift Out Slider?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 4200 Lift Out Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC FAR and product line FAR-M-20 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code FAR and product line FAR-M-20, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for KP Building Products Limited 4200 Lift Out Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)