Skip to main content
Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-309 ENERGY STAR Most Efficient Eligible

Marvin — Infinity Full Frame/Insert Casements · Casement Windows

Marvin Infinity Full Frame/Insert Casements is a Casement Windows assembly with a Fiberglass frame that reaches a minimum U-Factor of 0.19 across 540 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #564 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.30.

Min U-Factor
0.19
SHGC Range
0.12-0.30
Certified Options
540
Category Standing
#564 of 1,352

How does Marvin Infinity Full Frame/Insert Casements compare thermally against Window peers?

Marvin Infinity Full Frame/Insert Casements achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Infinity Full Frame/Insert CasementsHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Infinity Full Frame/Insert Casements (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Infinity Full Frame/Insert Casements Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 105 certified Marvin series, this Casement Windows offers a 0.13 U-Factor adjustment span between 0.32 entry options and 0.19 top-performing glazing. Category standing is #564/1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%).

Mapping NFRC SHGC values (0.12 to 0.30) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 44 configurations meet ENERGY STAR Most Efficient criteria while 58 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors MAR to 2025-08-06 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 114.0 BTU/hr conductive loss (-13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 540 certified glazing combinations for Infinity Full Frame/Insert Casements (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 58 packages (8 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 172 packages (16 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 228 packages (8 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 464 packages (36 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Milgard Manufacturing, Inc. — 12210 Vertical Slider Fiberglass 0.19 0.09 6,177
Milgard Manufacturing, Inc. — 12110 Horizontal Slider Fiberglass 0.19 0.09 6,182
Milgard Manufacturing, Inc. — 12410 Awning Window Fiberglass 0.19 0.09 9,064
Coeur D'Alene Window Company — 3511 Awning Window Vinyl 0.19 0.10 540
Coeur D'Alene Window Company — 3411 Casement Window Vinyl 0.19 0.10 542

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Full Frame/Insert Casements appear below.

How efficient is Marvin Infinity Full Frame/Insert Casements compared with peer Window models?

Across 540 tested NFRC glazing configurations, Marvin Infinity Full Frame/Insert Casements with Fiberglass framing and Casement Single-Vent (CSSV) style reaches a 0.19 minimum U-Factor and 0.12-0.30 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

Is Infinity Full Frame/Insert Casements approved for Northern Zone heating climates?

Yes. 58 packages in Marvin Infinity Full Frame/Insert Casements clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What BTU/hr heat transfer results from Infinity Full Frame/Insert Casements's 0.19 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Marvin Infinity Full Frame/Insert Casements?

Do not specify Infinity Full Frame/Insert Casements without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Full Frame/Insert Casements options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many Infinity Full Frame/Insert Casements glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 464 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Infinity Full Frame/Insert Casements, while total line SHGC reaches 0.30 in colder packages.

Which package tier in Infinity Full Frame/Insert Casements holds Most Efficient recognition?

Only 44 options out of 540 (8.1%) meet tighter Most Efficient U-Factor and SHGC thresholds in Marvin Infinity Full Frame/Insert Casements, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on Marvin Infinity Full Frame/Insert Casements in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Infinity Full Frame/Insert Casements installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Marvin Infinity Full Frame/Insert Casements units match permits?

Match the NFRC thermal sticker for code MAR and line MAR-N-309 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Full Frame/Insert Casements come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros