Window · Fiberglass Frame NFRC MIL · Product Line MIL-A-323 ENERGY STAR Most Efficient Eligible

Milgard Manufacturing, Inc. — 12410 Awning Window · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 9,064 variants inside Milgard Manufacturing, Inc. 12410 Awning Window, combining Fiberglass frame construction with U-Factors spanning 0.19 to 0.32 and SHGC 0.09 to 0.44. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #564 of 1,352 among 1,352 Window families and posts matches the 0.19 Btu/hr·ft²·°F median among Fiberglass peers.

Min U-Factor
0.19
SHGC Range
0.09-0.44
Certified Options
9,064
Category Standing
#564 of 1,352

How does Milgard Manufacturing, Inc. 12410 Awning Window compare thermally against Window peers?

Milgard Manufacturing, Inc. 12410 Awning Window achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 12410 Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 12410 Awning Window (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

12410 Awning Window Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Fiberglass cohort (0.19 median U-Factor), 12410 Awning Window reaches 0.19 on its lowest-conductivity package — #34 of 76 in Fiberglass, tied with 8 others at 0.19, more insulating than 44.7% of Fiberglass lines (At median vs Fiberglass peers). Pairing NFRC ID MIL across multi-pane fills shifts U-Factor from 0.32 down toward 0.19.

Regional qualification covers Northern, North-Central, South-Central, Southern. 235 configurations meet ENERGY STAR Most Efficient criteria while 318 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2026-03-27 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 9,064 certified glazing combinations for 12410 Awning Window (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 318 packages (67 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 720 packages (118 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 4,588 packages (100 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 8,901 packages (217 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Vivid Casement Fiberglass 0.19 0.06 1,650
Marvin — Vivid Awning Fiberglass 0.19 0.06 1,572
Marvin — Infinity Insert Glider Fiberglass 0.19 0.12 640
Marvin — Infinity Full Frame/Insert Casements Fiberglass 0.19 0.12 540
JELD-WEN, inc. — Premium Vinyl (V-4500) Tilt Double Hung Vinyl 0.19 0.11 9,104

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 12410 Awning Window appear below.

What thermal performance numbers separate Milgard Manufacturing, Inc. 12410 Awning Window from peers?

EPA ENERGY STAR v7.0 records 9,064 configurations for Milgard Manufacturing, Inc. 12410 Awning Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.19 versus a 0.20 Window median. Only 235 options earn Most Efficient status.

Which glazing options in Milgard Manufacturing, Inc. 12410 Awning Window meet Northern climate limits?

Milgard Manufacturing, Inc. 12410 Awning Window supplies 318 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How much winter heat loss does 12410 Awning Window conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 114.0 BTU/hr on 12410 Awning Window's lowest-U package (0.19), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What homeowner profiles are a poor match for Milgard Manufacturing, Inc. 12410 Awning Window?

Do not specify 12410 Awning Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 12410 Awning Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many 12410 Awning Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 8,901 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Milgard Manufacturing, Inc. 12410 Awning Window, while total line SHGC reaches 0.44 in colder packages.

Are all 9,064 12410 Awning Window configurations ENERGY STAR Most Efficient?

No. Exactly 235 of 9,064 configurations (2.6%) earn ENERGY STAR Most Efficient status in 12410 Awning Window; the remaining standard v7.0 options pass base zone limits only.

Do 2026 12410 Awning Window installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 12410 Awning Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 12410 Awning Window?

Inspectors match the temporary NFRC sticker (U 0.19-0.32, SHGC 0.09-0.44) against permit drawings for line MIL-A-323. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 12410 Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros