Marvin — Infinity Insert Glider · Single Slider
Positioning #564/1,352 in certified Window, Marvin Infinity Insert Glider pairs Fiberglass frame construction with 640 glazing options rated between 0.12 and 0.32 SHGC across Northern, North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.19 to 0.32 U-Factor and the line includes 40 ENERGY STAR Most Efficient packages (6.2% of line).
- Min U-Factor
- 0.19
- SHGC Range
- 0.12-0.32
- Certified Options
- 640
- Category Standing
- #564 of 1,352
How does Marvin Infinity Insert Glider compare thermally against Window peers?
Marvin Infinity Insert Glider achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 105 certified Marvin series, this Single Slider offers a 0.13 U-Factor adjustment span between 0.32 entry options and 0.19 top-performing glazing. Category standing is #564/1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%).
Mapping NFRC SHGC values (0.12 to 0.32) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 40 configurations meet ENERGY STAR Most Efficient criteria while 62 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-08-08.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 640 certified glazing combinations for Infinity Insert Glider (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 62 packages (8 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 216 packages (16 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 298 packages (8 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 568 packages (32 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Milgard Manufacturing, Inc. — 12210 Vertical Slider | Fiberglass | 0.19 | 0.09 | 6,177 |
| Milgard Manufacturing, Inc. — 12110 Horizontal Slider | Fiberglass | 0.19 | 0.09 | 6,182 |
| Milgard Manufacturing, Inc. — 12410 Awning Window | Fiberglass | 0.19 | 0.09 | 9,064 |
| Harvey Industries, Inc. — Welded Vinyl Rolling Window | Vinyl | 0.19 | 0.16 | 653 |
| Lindsay Windows — Pinnacle / Healthy Double Slider | Vinyl | 0.19 | 0.15 | 670 |
What other certified series does Marvin produce?
Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Ultimate Direct Glaze Rectangle / Polygon
U-Factor 0.13–0.32 · 34,184 certified options.
Ultimate Wood Direct Glaze Rectangle / Polygon
U-Factor 0.13–0.32 · 13,899 certified options.
Ultimate Wood Direct Glaze Round Top
U-Factor 0.13–0.32 · 8,590 certified options.
Ultimate Wood Double Hung / Single Hung
U-Factor 0.13–0.32 · 2,649 certified options.
Ultimate Wood Double Hung / Single Hung Magnum
U-Factor 0.13–0.32 · 2,481 certified options.
Modern Direct Glaze Rectangle/Polygon
U-Factor 0.14–0.32 · 2,988 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Insert Glider appear below.
Where does Marvin Infinity Insert Glider stand thermally among ENERGY STAR Window lines?
Built with Fiberglass framing in Horizontal Slider (HSOX) style, Marvin Infinity Insert Glider offers 640 Version 7.0 configurations from U 0.19 up to 0.32, posting -0.01 against the Window median of 0.20 with 40 Most Efficient picks.
Does Marvin Infinity Insert Glider qualify for the ENERGY STAR Northern Zone?
Prescriptive Northern compliance covers 62 Infinity Insert Glider packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.
What conductive BTU/hr difference separates Infinity Insert Glider from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make Infinity Insert Glider the wrong window or door choice?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Insert Glider options exceeding U 0.22. Verify whether your municipal code restricts Fiberglass frames in wildfire or historic zones.
Is Infinity Insert Glider suitable for sunbelt cooling-dominated homes?
Warm-climate homeowners have 568 Southern-approved options within Infinity Insert Glider spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Does Infinity Insert Glider carry EPA Most Efficient certification across its lineup?
No. Exactly 40 of 640 configurations (6.2%) earn ENERGY STAR Most Efficient status in Infinity Insert Glider; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to Infinity Insert Glider?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Infinity Insert Glider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on Infinity Insert Glider?
Confirm both the paper NFRC label and permanent corner glass etch match line MAR-N-265 and NFRC ID MAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Insert Glider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)