Skip to main content
Window · Fiberglass Frame NFRC MIL · Product Line MIL-A-270

Milgard Manufacturing, Inc. — 3644/3664 Panel Set Transom Inswing · Picture Window

Positioning #936/1,352 in certified Window, Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing pairs Fiberglass frame construction with 2,958 glazing options rated between 0.09 and 0.37 SHGC across Northern, North-Central, South-Central, Southern. Across 58 certified Milgard Manufacturing, Inc. product families, its thermal resistance spans 0.23 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.23
SHGC Range
0.09-0.37
Certified Options
2,958
Category Standing
#936 of 1,352

How does Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing compare thermally against Window peers?

Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3644/3664 Panel Set Transom InswingHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 3644/3664 Panel Set Transom Inswing (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3644/3664 Panel Set Transom Inswing Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing at rank #936 of 1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.37 band.

Climate coverage for Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 3 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-02-13.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,958 certified glazing combinations for 3644/3664 Panel Set Transom Inswing (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 3 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 64 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 576 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,946 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Vivid Double Hung Picture / Insert Picture Fiberglass 0.23 0.06 1,087
Pella Corporation — Impervia Sliding Window Fiberglass 0.23 0.12 670
Pella Corporation — Impervia Single Hung Fiberglass 0.23 0.12 574
Pella Corporation — Impervia Double Hung Fiberglass 0.23 0.13 450
Marvin — Essential Casement Picture Fiberglass 0.23 0.18 316

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing appear below.

How efficient is Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing compared with peer Window models?

Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing spans 2,958 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.09 to 0.37. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above 3644/3664 Panel Set Transom Inswing's 0.23 minimum. However, 3 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

What BTU/hr heat transfer results from 3644/3664 Panel Set Transom Inswing's 0.23 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 3644/3664 Panel Set Transom Inswing at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 3644/3664 Panel Set Transom Inswing options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 3644/3664 Panel Set Transom Inswing suitable for sunbelt cooling-dominated homes?

Yes, 3644/3664 Panel Set Transom Inswing holds 2,946 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.09 SHGC in cooling climates.

What glazing share inside 3644/3664 Panel Set Transom Inswing qualifies as Most Efficient?

All 2,958 3644/3664 Panel Set Transom Inswing listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 3644/3664 Panel Set Transom Inswing window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Milgard Manufacturing, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify 3644/3664 Panel Set Transom Inswing after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MIL and product line MIL-A-270, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3644/3664 Panel Set Transom Inswing come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros