Skip to main content
Window · Fiberglass Frame NFRC PEL · Product Line PEL-N-102

Pella Corporation — Impervia Single Hung · Single Hung

Pella Corporation Impervia Single Hung is a Single Hung assembly with a Fiberglass frame that reaches a minimum U-Factor of 0.23 across 574 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.48.

Min U-Factor
0.23
SHGC Range
0.12-0.48
Certified Options
574
Category Standing
#936 of 1,352

How does Pella Corporation Impervia Single Hung compare thermally against Window peers?

Pella Corporation Impervia Single Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Impervia Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Impervia Single Hung (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Impervia Single Hung Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Impervia Single Hung spans 574 NFRC test records (PEL), ranking #936 of 1,352 Window families (tied with 97 others at 0.23, more insulating than 23.6% of Window lines). Its 0.23 thermal floor compares at +0.04 against the Fiberglass median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 17 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors PEL to 2024-05-02 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 574 certified glazing combinations for Impervia Single Hung (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 17 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 72 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 213 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 517 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Essential Casement Picture Fiberglass 0.23 0.18 316
Marvin — Essential Double Hung Picture Fiberglass 0.23 0.20 101
Marvin — Vivid Double Hung Picture / Insert Picture Fiberglass 0.23 0.06 1,087
Milgard Manufacturing, Inc. — 3644/3664 Panel Set Transom Inswing Fiberglass 0.23 0.09 2,958
Milgard Manufacturing, Inc. — 3647/3667 Outswing Panel Glazed Transom Fiberglass 0.23 0.09 3,017

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Impervia Single Hung appear below.

How efficient is Pella Corporation Impervia Single Hung compared with peer Window models?

Built with Fiberglass framing in Single-Hung (VSSH) style, Pella Corporation Impervia Single Hung offers 574 Version 7.0 configurations from U 0.23 up to 0.32, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

Does Pella Corporation Impervia Single Hung qualify for the ENERGY STAR Northern Zone?

With a 0.23 minimum U-Factor, Pella Corporation Impervia Single Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 17 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How much winter heat loss does Impervia Single Hung conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Pella Corporation Impervia Single Hung?

Do not specify Impervia Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Impervia Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many Impervia Single Hung glazing packages pass Southern solar-heat rules?

Exactly 517 Impervia Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.48 glass.

Which package tier in Impervia Single Hung holds Most Efficient recognition?

No. Zero of the 574 configurations in Pella Corporation Impervia Single Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Do 2026 Impervia Single Hung installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC PEL and product line PEL-N-102 on delivery?

Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.12-0.48) against permit drawings for line PEL-N-102. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Impervia Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros