Skip to main content
Window · Fiberglass Frame NFRC MIL · Product Line MIL-A-271

Milgard Manufacturing, Inc. — 3647/3667 Outswing Panel Glazed Transom · Picture Window

Positioning #936/1,352 in certified Window, Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom pairs Fiberglass frame construction with 3,017 glazing options rated between 0.09 and 0.37 SHGC across Northern, North-Central, South-Central, Southern. Across 58 certified Milgard Manufacturing, Inc. product families, its thermal resistance spans 0.23 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.23
SHGC Range
0.09-0.37
Certified Options
3,017
Category Standing
#936 of 1,352

How does Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom compare thermally against Window peers?

Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3647/3667 Outswing Panel Glazed TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 3647/3667 Outswing Panel Glazed Transom (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3647/3667 Outswing Panel Glazed Transom Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Fiberglass cohort (0.19 median U-Factor), 3647/3667 Outswing Panel Glazed Transom reaches 0.23 on its lowest-conductivity package — #54 of 76 in Fiberglass, tied with 12 others at 0.23, more insulating than 13.2% of Fiberglass lines (+0.04 vs Fiberglass peers). Pairing NFRC ID MIL across multi-pane fills shifts U-Factor from 0.32 down toward 0.23.

Mapping NFRC SHGC values (0.09 to 0.37) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 3 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-02-13 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,017 certified glazing combinations for 3647/3667 Outswing Panel Glazed Transom (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 3 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 68 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 679 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,004 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Vivid Double Hung Picture / Insert Picture Fiberglass 0.23 0.06 1,087
Pella Corporation — Impervia Sliding Window Fiberglass 0.23 0.12 670
Pella Corporation — Impervia Single Hung Fiberglass 0.23 0.12 574
Pella Corporation — Impervia Double Hung Fiberglass 0.23 0.13 450
Marvin — Essential Casement Picture Fiberglass 0.23 0.18 316

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom appear below.

How well does 3647/3667 Outswing Panel Glazed Transom by Milgard Manufacturing, Inc. insulate relative to Window benchmarks?

Across 3,017 tested NFRC glazing configurations, Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom with Fiberglass framing and Fixed Window (FIXD) style reaches a 0.23 minimum U-Factor and 0.09-0.37 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.

Is 3647/3667 Outswing Panel Glazed Transom approved for Northern Zone heating climates?

With a 0.23 minimum U-Factor, Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom cannot satisfy prescriptive <= 0.22 Northern targets, yet 3 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What conductive BTU/hr difference separates 3647/3667 Outswing Panel Glazed Transom from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on 3647/3667 Outswing Panel Glazed Transom's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What homeowner profiles are a poor match for Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 3647/3667 Outswing Panel Glazed Transom options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in 3647/3667 Outswing Panel Glazed Transom?

Yes, 3647/3667 Outswing Panel Glazed Transom holds 3,004 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.09 SHGC in cooling climates.

What glazing share inside 3647/3667 Outswing Panel Glazed Transom qualifies as Most Efficient?

All 3,017 3647/3667 Outswing Panel Glazed Transom listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect 3647/3667 Outswing Panel Glazed Transom?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 3647/3667 Outswing Panel Glazed Transom installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 3647/3667 Outswing Panel Glazed Transom after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MIL and product line MIL-A-271, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3647/3667 Outswing Panel Glazed Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros