Pella Corporation — Impervia Double Hung · Double Hung
Across 39 Pella Corporation certified families, Impervia Double Hung supplies 450 Double Hung configurations starting at 0.23 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.48 SHGC. Its thermal floor ranks #936 of 1,352 category entries—0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.23
- SHGC Range
- 0.13-0.48
- Certified Options
- 450
- Category Standing
- #936 of 1,352
How does Pella Corporation Impervia Double Hung compare thermally against Window peers?
Pella Corporation Impervia Double Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Pella Corporation Impervia Double Hung standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.
Climate coverage for Pella Corporation Impervia Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 24 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-05-02.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 450 certified glazing combinations for Impervia Double Hung (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 24 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 76 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 156 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 390 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Essential Casement Picture | Fiberglass | 0.23 | 0.18 | 316 |
| Marvin — Essential Double Hung Picture | Fiberglass | 0.23 | 0.20 | 101 |
| Marvin — Vivid Double Hung Picture / Insert Picture | Fiberglass | 0.23 | 0.06 | 1,087 |
| Milgard Manufacturing, Inc. — 3644/3664 Panel Set Transom Inswing | Fiberglass | 0.23 | 0.09 | 2,958 |
| Milgard Manufacturing, Inc. — 3647/3667 Outswing Panel Glazed Transom | Fiberglass | 0.23 | 0.09 | 3,017 |
What other certified series does Pella Corporation produce?
Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Pella Entry Doors - Wood Edge Steel Door
U-Factor 0.13–0.28 · 76,045 certified options.
250 Series / Power Symphony Fixed
U-Factor 0.14–0.32 · 266 certified options.
250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement
U-Factor 0.15–0.32 · 144 certified options.
Architect Wood Fixed Casement
U-Factor 0.15–0.32 · 2,468 certified options.
Pella Entry Doors - Fiberglass Skin Door
U-Factor 0.15–0.28 · 242,982 certified options.
Pella Entry Doors - Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 319,127 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Impervia Double Hung appear below.
Where does Pella Corporation Impervia Double Hung stand thermally among ENERGY STAR Window lines?
Pella Corporation Impervia Double Hung spans 450 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.13 to 0.48. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.
How does Pella Corporation Impervia Double Hung satisfy Version 7.0 Northern criteria?
Northern qualification on Impervia Double Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 24 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How do you calculate winter heat conduction for Pella Corporation Impervia Double Hung?
At U 0.23, a standard 3x5 ft (15 sq ft) Impervia Double Hung opening transfers 138.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +6.0 BTU/hr difference.
Who should NOT choose Pella Corporation Impervia Double Hung for a residential project?
Skip Impervia Double Hung if local historic preservation boards prohibit Fiberglass profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Impervia Double Hung options exceeding U 0.22.
Is Impervia Double Hung suitable for sunbelt cooling-dominated homes?
Warm-climate homeowners have 390 Southern-approved options within Impervia Double Hung spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside Impervia Double Hung qualifies as Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 450 Impervia Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Do 2026 Impervia Double Hung installations qualify for IRS Section 25C tax credits?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Impervia Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on Impervia Double Hung?
Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.13-0.48) against permit drawings for line PEL-N-126. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Pella Corporation Impervia Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)