Milgard Manufacturing, Inc. — 3646/3666 Transom · Picture Window
EPA ENERGY STAR Version 7.0 certifies 3,449 variants inside Milgard Manufacturing, Inc. 3646/3666 Transom, combining Fiberglass frame construction with U-Factors spanning 0.17 to 0.32 and SHGC 0.10 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Fiberglass peers.
- Min U-Factor
- 0.17
- SHGC Range
- 0.10-0.52
- Certified Options
- 3,449
- Category Standing
- #362 of 1,352
How does Milgard Manufacturing, Inc. 3646/3666 Transom compare thermally against Window peers?
Milgard Manufacturing, Inc. 3646/3666 Transom achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 3646/3666 Transom is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Fiberglass frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 103 configurations meet ENERGY STAR Most Efficient criteria while 475 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2025-02-13 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 3,449 certified glazing combinations for 3646/3666 Transom (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 475 packages (81 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,365 packages (72 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 1,795 packages (36 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 2,512 packages (58 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Vivd Casement Picture | Fiberglass | 0.17 | 0.07 | 1,802 |
| Marvin — Infinity Double Hung Picture | Fiberglass | 0.17 | 0.07 | 695 |
| Marvin — Infinity Insert Double Hung Picture | Fiberglass | 0.17 | 0.07 | 685 |
| Andersen Corporation — 400 Series Specialty Window - Double Hung Half Circle | Wood | 0.17 | 0.15 | 2,938 |
| Amsco Windows — VZ1 Hampton PM Fixed | Vinyl | 0.17 | 0.11 | 2,764 |
What other certified series does Milgard Manufacturing, Inc. produce?
Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8521T2.8531T2.8571T2 Casement Fixed
U-Factor 0.13–0.32 · 23,185 certified options.
8320T2.8330T2 Picture Window
U-Factor 0.14–0.32 · 22,562 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3646/3666 Transom appear below.
How well does 3646/3666 Transom by Milgard Manufacturing, Inc. insulate relative to Window benchmarks?
Built with Fiberglass framing in Fixed Window (FIXD) style, Milgard Manufacturing, Inc. 3646/3666 Transom offers 3,449 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 103 Most Efficient picks.
Can homeowners install 3646/3666 Transom in cold Northern ENERGY STAR counties?
Milgard Manufacturing, Inc. 3646/3666 Transom supplies 475 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.
How does a 3x5 ft 3646/3666 Transom window perform under a 40 deg F temperature drop?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip Milgard Manufacturing, Inc. 3646/3666 Transom and compare alternatives?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 3646/3666 Transom options exceeding U 0.22. Verify whether your municipal code restricts Fiberglass frames in wildfire or historic zones.
What Southern ENERGY STAR v7.0 options exist in 3646/3666 Transom?
Exactly 2,512 3646/3666 Transom options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.10 rather than higher 0.52 glass.
How many Milgard Manufacturing, Inc. 3646/3666 Transom variants earn ENERGY STAR Most Efficient?
No. Exactly 103 of 3,449 configurations (3.0%) earn ENERGY STAR Most Efficient status in 3646/3666 Transom; the remaining standard v7.0 options pass base zone limits only.
Do 2026 3646/3666 Transom installations qualify for IRS Section 25C tax credits?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
What permanent glass etch marks verify 3646/3666 Transom after sticker removal?
Verify NFRC ID MIL and series MIL-A-247 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3646/3666 Transom come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)