Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-7 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 400 Series Specialty Window - Double Hung Half Circle · Picture Window

Across 111 Andersen Corporation certified families, 400 Series Specialty Window - Double Hung Half Circle supplies 2,938 Picture Window configurations starting at 0.17 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.15-0.51
Certified Options
2,938
Category Standing
#362 of 1,352

How does Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle compare thermally against Window peers?

Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Specialty Window - Double Hung Half CircleHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 400 Series Specialty Window - Double Hung Half Circle (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Specialty Window - Double Hung Half Circle Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 400 Series Specialty Window - Double Hung Half Circle spans 2,938 NFRC test records (AND), ranking #362 of 1,352 Window families (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%). Its 0.17 thermal floor compares at -0.04 against the Wood median (0.21).

Climate coverage for Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 294 configurations meet ENERGY STAR Most Efficient criteria while 650 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2024-03-19.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,938 certified glazing combinations for 400 Series Specialty Window - Double Hung Half Circle (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 650 packages (68 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,274 packages (109 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,444 packages (64 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,154 packages (236 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle appear below.

What thermal performance numbers separate Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle from peers?

Built with Wood framing in Fixed Window (FIXD) style, Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle offers 2,938 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 294 Most Efficient picks.

Is 400 Series Specialty Window - Double Hung Half Circle approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 650 400 Series Specialty Window - Double Hung Half Circle packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from 400 Series Specialty Window - Double Hung Half Circle's 0.17 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400 Series Specialty Window - Double Hung Half Circle at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Specialty Window - Double Hung Half Circle options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Is 400 Series Specialty Window - Double Hung Half Circle suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 2,154 Southern-approved options within 400 Series Specialty Window - Double Hung Half Circle spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in 400 Series Specialty Window - Double Hung Half Circle holds Most Efficient recognition?

Within 400 Series Specialty Window - Double Hung Half Circle, 10.0% (294 of 2,938) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What 2026 federal tax credit and Lead RRP rules apply to 400 Series Specialty Window - Double Hung Half Circle?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle units match permits?

Verify NFRC ID AND and series AND-N-7 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Specialty Window - Double Hung Half Circle come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros