Skip to main content
Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-268 ENERGY STAR Most Efficient Eligible

Marvin — Infinity Double Hung Picture · Picture Window

Positioning #362/1,352 in certified Window, Marvin Infinity Double Hung Picture pairs Fiberglass frame construction with 695 glazing options rated between 0.07 and 0.33 SHGC across Northern, North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 116 ENERGY STAR Most Efficient packages (16.7% of line).

Min U-Factor
0.17
SHGC Range
0.07-0.33
Certified Options
695
Category Standing
#362 of 1,352

How does Marvin Infinity Double Hung Picture compare thermally against Window peers?

Marvin Infinity Double Hung Picture achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Infinity Double Hung PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Infinity Double Hung Picture (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Infinity Double Hung Picture Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 105 certified Marvin series, this Picture Window offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Mapping NFRC SHGC values (0.07 to 0.33) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 116 configurations meet ENERGY STAR Most Efficient criteria while 144 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-05-14. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 695 certified glazing combinations for Infinity Double Hung Picture (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 144 packages (42 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 320 packages (70 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 349 packages (36 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 555 packages (82 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Double Hung Picture appear below.

How efficient is Marvin Infinity Double Hung Picture compared with peer Window models?

Across 695 tested NFRC glazing configurations, Marvin Infinity Double Hung Picture with Fiberglass framing and Fixed Window (FIXD) style reaches a 0.17 minimum U-Factor and 0.07-0.33 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

Is Infinity Double Hung Picture approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 144 Infinity Double Hung Picture packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How much winter heat loss does Infinity Double Hung Picture conduct across a 15 sq ft opening?

Using NFRC MAR U-Factor 0.17, a 15 sq ft Fixed Window (FIXD) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

What are the practical limitations of specifying Infinity Double Hung Picture?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Double Hung Picture options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does Infinity Double Hung Picture meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Infinity Double Hung Picture holds 555 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

How many Marvin Infinity Double Hung Picture variants earn ENERGY STAR Most Efficient?

Only 116 options out of 695 (16.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Marvin Infinity Double Hung Picture, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Infinity Double Hung Picture?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify Infinity Double Hung Picture glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.17-0.32, SHGC 0.07-0.33) against permit drawings for line MAR-N-268. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Double Hung Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros