Door · Fiberglass Frame NFRC MIL · Product Line MIL-A-278

Milgard Manufacturing, Inc. — 3945/3965 Outswing Patio Door · Swinging Entry Door (Single)

EPA ENERGY STAR Version 7.0 certifies 977 variants inside Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door, combining Fiberglass frame construction with U-Factors spanning 0.24 to 0.28 and SHGC 0.12 to 0.32. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Single family places #199 of 268 among 268 Door families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Fiberglass peers.

Min U-Factor
0.24
SHGC Range
0.12-0.32
Certified Options
977
Category Standing
#199 of 268

How does Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door compare thermally against Door peers?

Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 3945/3965 Outswing Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 3945/3965 Outswing Patio Door (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

3945/3965 Outswing Patio Door Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), 3945/3965 Outswing Patio Door is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Fiberglass frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.28.

Climate coverage for Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 113 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-05-30 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 977 certified glazing combinations for 3945/3965 Outswing Patio Door (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 113 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 113 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 953 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 953 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door appear below.

How well does 3945/3965 Outswing Patio Door by Milgard Manufacturing, Inc. insulate relative to Door benchmarks?

Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door spans 977 certified configurations with U-Factors between 0.24 and 0.28 and SHGC values from 0.12 to 0.32. Ranked #199 of 268 Door families, it carries 0 Most Efficient options.

Is 3945/3965 Outswing Patio Door approved for Northern Zone heating climates?

Prescriptive Northern approval ends at U <= 0.22, above 3945/3965 Outswing Patio Door's 0.24 minimum. However, 113 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How much winter heat loss does 3945/3965 Outswing Patio Door conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 3945/3965 Outswing Patio Door's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

Which situations make 3945/3965 Outswing Patio Door the wrong window or door choice?

Do not specify 3945/3965 Outswing Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 3945/3965 Outswing Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does 3945/3965 Outswing Patio Door meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 953 Southern-approved options within 3945/3965 Outswing Patio Door spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 3945/3965 Outswing Patio Door qualifies as Most Efficient?

No. Zero of the 977 configurations in Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to 3945/3965 Outswing Patio Door?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on 3945/3965 Outswing Patio Door?

Inspectors match the temporary NFRC sticker (U 0.24-0.28, SHGC 0.12-0.32) against permit drawings for line MIL-A-278. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros