Skip to main content
Window · Vinyl Frame NFRC MIL · Product Line MIL-A-154

Milgard Manufacturing, Inc. — 6210.6211.6230.6230J.6270 Single Hung · Single Hung

Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 3,934 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.52.

Min U-Factor
0.24
SHGC Range
0.11-0.52
Certified Options
3,934
Category Standing
#1,034 of 1,352

How does Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung compare thermally against Window peers?

Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6210.6211.6230.6230J.6270 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 6210.6211.6230.6230J.6270 Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6210.6211.6230.6230J.6270 Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 58 certified Milgard Manufacturing, Inc. series, this Single Hung offers a 0.08 U-Factor adjustment span between 0.32 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 194 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2024-11-25 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,934 certified glazing combinations for 6210.6211.6230.6230J.6270 Single Hung (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 194 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 705 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,726 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,476 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung appear below.

What thermal performance numbers separate Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung from peers?

Across 3,934 tested NFRC glazing configurations, Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.24 minimum U-Factor and 0.11-0.52 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

Which glazing options in Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung meet Northern climate limits?

With a 0.24 minimum U-Factor, Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 194 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What conductive BTU/hr difference separates 6210.6211.6230.6230J.6270 Single Hung from the 0.22 Northern rule?

Using NFRC MIL U-Factor 0.24, a 15 sq ft Single-Hung (VSSH) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

Which situations make 6210.6211.6230.6230J.6270 Single Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 6210.6211.6230.6230J.6270 Single Hung options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 6210.6211.6230.6230J.6270 Single Hung suitable for sunbelt cooling-dominated homes?

Yes, 6210.6211.6230.6230J.6270 Single Hung holds 3,476 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

What glazing share inside 6210.6211.6230.6230J.6270 Single Hung qualifies as Most Efficient?

6210.6211.6230.6230J.6270 Single Hung holds zero Most Efficient entries across its 3,934 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect 6210.6211.6230.6230J.6270 Single Hung?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 6210.6211.6230.6230J.6270 Single Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC MIL and product line MIL-A-154 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MIL and product line MIL-A-154, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 6210.6211.6230.6230J.6270 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros