Skip to main content
Window · Vinyl Frame NFRC SBP · Product Line SBP-A-14

Simonton Building Products, Inc. - Simonton Windows — 43-06 / 43-17 Single Hung · Single Hung

Simonton Building Products, Inc. - Simonton Windows engineered the 43-06 / 43-17 Single Hung Single Hung line for Northern, North-Central, South-Central, Southern, certifying 4,076 glass-spacer combinations from 0.24 to 0.32 U-Factor and 0.11 to 0.51 SHGC. Relative to other Vinyl models tracked under NFRC SBP, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.11-0.51
Certified Options
4,076
Category Standing
#1,034 of 1,352

How does Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung compare thermally against Window peers?

Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 43-06 / 43-17 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 43-06 / 43-17 Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

43-06 / 43-17 Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 43-06 / 43-17 Single Hung spans 4,076 NFRC test records (SBP), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).

Climate coverage for Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 79 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-02-08 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,076 certified glazing combinations for 43-06 / 43-17 Single Hung (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 79 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 289 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,289 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,891 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?

Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung appear below.

Where does Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 4,076 configurations for Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung qualify for the ENERGY STAR Northern Zone?

While Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung misses the <= 0.22 prescriptive mark (floor U 0.24), 79 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How much winter heat loss does 43-06 / 43-17 Single Hung conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 43-06 / 43-17 Single Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 43-06 / 43-17 Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung in Southern or South-Central zones?

Yes, 43-06 / 43-17 Single Hung holds 3,891 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

Does 43-06 / 43-17 Single Hung carry EPA Most Efficient certification across its lineup?

43-06 / 43-17 Single Hung holds zero Most Efficient entries across its 4,076 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on 43-06 / 43-17 Single Hung?

Verify NFRC ID SBP and series SBP-A-14 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 43-06 / 43-17 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)