Skip to main content
Window · Vinyl Frame NFRC SBP · Product Line SBP-A-29

Simonton Building Products, Inc. - Simonton Windows — 43-40 Double Slider · Double Slider

Simonton Building Products, Inc. - Simonton Windows engineered the 43-40 Double Slider Double Slider line for Northern, North-Central, South-Central, Southern, certifying 3,537 glass-spacer combinations from 0.24 to 0.32 U-Factor and 0.08 to 0.48 SHGC. Relative to other Vinyl models tracked under NFRC SBP, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.08-0.48
Certified Options
3,537
Category Standing
#1,034 of 1,352

How does Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider compare thermally against Window peers?

Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 43-40 Double SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 43-40 Double Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

43-40 Double Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 43-40 Double Slider reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID SBP across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.

Mapping NFRC SHGC values (0.08 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 220 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-08-23 and cert timestamp 2024-04-19.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,537 certified glazing combinations for 43-40 Double Slider (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 220 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 523 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,612 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,144 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?

Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider appear below.

How efficient is Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider compared with peer Window models?

EPA ENERGY STAR v7.0 records 3,537 configurations for Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern approval ends at U <= 0.22, above 43-40 Double Slider's 0.24 minimum. However, 220 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How much winter heat loss does 43-40 Double Slider conduct across a 15 sq ft opening?

At U 0.24, a standard 3x5 ft (15 sq ft) 43-40 Double Slider opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

What are the practical limitations of specifying 43-40 Double Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 43-40 Double Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 43-40 Double Slider?

Warm-climate homeowners have 3,144 Southern-approved options within 43-40 Double Slider spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in 43-40 Double Slider holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 3,537 43-40 Double Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on 43-40 Double Slider?

Match the NFRC thermal sticker for code SBP and line SBP-A-29 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 43-40 Double Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros