Skip to main content
Door · Wood Frame NFRC PEL · Product Line PEL-N-221

Pella Corporation — CIS01 - Clad Wood Inswing Hinged Door · Swinging Entry Door (Single)

Pella Corporation engineered the CIS01 - Clad Wood Inswing Hinged Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 79 glass-spacer combinations from 0.23 to 0.28 U-Factor and 0.10 to 0.39 SHGC. Relative to other Wood models tracked under NFRC PEL, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.10-0.39
Certified Options
79
Category Standing
#162 of 268

How does Pella Corporation CIS01 - Clad Wood Inswing Hinged Door compare thermally against Door peers?

Pella Corporation CIS01 - Clad Wood Inswing Hinged Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. CIS01 - Clad Wood Inswing Hinged DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing CIS01 - Clad Wood Inswing Hinged Door (U 0.23).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.23430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

CIS01 - Clad Wood Inswing Hinged Door Cohort StandingMin U-Factor 0.23 stands at rank #162 of 268, outperforming 26.1% of peers.Min U-Factor 0.23Rank #162 of 268 (26.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), CIS01 - Clad Wood Inswing Hinged Door is 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 63 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2026-08-05 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 79 certified glazing combinations for CIS01 - Clad Wood Inswing Hinged Door (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 63 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 63 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 64 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 64 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation CIS01 - Clad Wood Inswing Hinged Door appear below.

How efficient is Pella Corporation CIS01 - Clad Wood Inswing Hinged Door compared with peer Door models?

EPA ENERGY STAR v7.0 records 79 configurations for Pella Corporation CIS01 - Clad Wood Inswing Hinged Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Can homeowners install CIS01 - Clad Wood Inswing Hinged Door in cold Northern ENERGY STAR counties?

While Pella Corporation CIS01 - Clad Wood Inswing Hinged Door misses the <= 0.22 prescriptive mark (floor U 0.23), 63 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How do you calculate winter heat conduction for Pella Corporation CIS01 - Clad Wood Inswing Hinged Door?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make CIS01 - Clad Wood Inswing Hinged Door the wrong window or door choice?

Skip CIS01 - Clad Wood Inswing Hinged Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on CIS01 - Clad Wood Inswing Hinged Door options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in CIS01 - Clad Wood Inswing Hinged Door?

Exactly 64 CIS01 - Clad Wood Inswing Hinged Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.10 rather than higher 0.39 glass.

What glazing share inside CIS01 - Clad Wood Inswing Hinged Door qualifies as Most Efficient?

No. Zero of the 79 configurations in Pella Corporation CIS01 - Clad Wood Inswing Hinged Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Do 2026 CIS01 - Clad Wood Inswing Hinged Door installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC PEL and product line PEL-N-221 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code PEL and product line PEL-N-221, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation CIS01 - Clad Wood Inswing Hinged Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros