Andersen Corporation — 400 Series Frenchwood® Gliding Patio Door · Sliding Patio Door
Andersen Corporation engineered the 400 Series Frenchwood® Gliding Patio Door Sliding Patio Door line for Northern, North-Central, South-Central, Southern, certifying 498 glass-spacer combinations from 0.23 to 0.28 U-Factor and 0.11 to 0.36 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.23
- SHGC Range
- 0.11-0.36
- Certified Options
- 498
- Category Standing
- #162 of 268
How does Andersen Corporation 400 Series Frenchwood® Gliding Patio Door compare thermally against Door peers?
Andersen Corporation 400 Series Frenchwood® Gliding Patio Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), 400 Series Frenchwood® Gliding Patio Door reaches 0.23 on its lowest-conductivity package — #246 of 408 in Wood, tied with 33 others at 0.23, more insulating than 31.6% of Wood lines (+0.02 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.28 down toward 0.23.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 186 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2024-04-18 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 498 certified glazing combinations for 400 Series Frenchwood® Gliding Patio Door (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 186 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 186 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 448 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 448 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Siteline Clad Wood Low Friction Gliding Door | Wood | 0.23 | 0.16 | 194 |
| JELD-WEN, inc. — Custom Clad HGD Outswing Door | Wood | 0.23 | 0.14 | 146 |
| Pella Corporation — CIS01 - Clad Wood Inswing Hinged Door | Wood | 0.23 | 0.10 | 79 |
| JELD-WEN, inc. — Siteline Clad Swinging Door | Wood | 0.23 | 0.11 | 971 |
| Weather Shield Mfg., Inc. — 8622 Premium / 8623 Contemporary Bi-Fold Door | Wood | 0.23 | 0.10 | 1,008 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Frenchwood® Gliding Patio Door appear below.
What U-Factor and SHGC range does Andersen Corporation 400 Series Frenchwood® Gliding Patio Door achieve?
EPA ENERGY STAR v7.0 records 498 configurations for Andersen Corporation 400 Series Frenchwood® Gliding Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.21 Door median. Only 0 options earn Most Efficient status.
How does Andersen Corporation 400 Series Frenchwood® Gliding Patio Door satisfy Version 7.0 Northern criteria?
Because 400 Series Frenchwood® Gliding Patio Door starts at 0.23 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 186 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
How does a 3x5 ft 400 Series Frenchwood® Gliding Patio Door window perform under a 40 deg F temperature drop?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on 400 Series Frenchwood® Gliding Patio Door's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.
Who should NOT choose Andersen Corporation 400 Series Frenchwood® Gliding Patio Door for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Frenchwood® Gliding Patio Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many 400 Series Frenchwood® Gliding Patio Door glazing packages pass Southern solar-heat rules?
Yes, 400 Series Frenchwood® Gliding Patio Door holds 448 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.
Which package tier in 400 Series Frenchwood® Gliding Patio Door holds Most Efficient recognition?
ENERGY STAR Most Efficient designation is absent across all 498 400 Series Frenchwood® Gliding Patio Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Do 2026 400 Series Frenchwood® Gliding Patio Door installations qualify for IRS Section 25C tax credits?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 400 Series Frenchwood® Gliding Patio Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC AND and product line AND-N-6 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-6 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Frenchwood® Gliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)