Pella Corporation — Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 · Double Hung
With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 spans 168 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code PEL, the Other / Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.49.
- Min U-Factor
- 0.25
- SHGC Range
- 0.12-0.49
- Certified Options
- 168
- Category Standing
- #1,174 of 1,352
How does Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 compare thermally against Window peers?
Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Other / Wood cohort (0.18 median U-Factor), Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 reaches 0.25 on its lowest-conductivity package — #6 of 6 in Other / Wood, lowest-ranked of 6 Other / Wood lines (+0.07 vs Other / Wood peers). Pairing NFRC ID PEL across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2025-04-24 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 168 certified glazing combinations for Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 46 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 160 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Anlin Industries — Monte Verde Horizontal Sliding | Vinyl | 0.25 | 0.13 | 173 |
| Anlin Industries — Monte Verde Single Hung | Vinyl | 0.25 | 0.13 | 179 |
| Custom Window Systems, Inc. — PW-8300 Fixed | Vinyl | 0.25 | 0.15 | 150 |
| Weather Shield Mfg., Inc. — 8120/1104/1105 Double Hung | Wood | 0.25 | 0.11 | 199 |
| Burris Windows — TectView AC Single Hung | Vinyl | 0.25 | 0.12 | 135 |
What other certified series does Pella Corporation produce?
Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Pella Entry Doors - Wood Edge Steel Door
U-Factor 0.13–0.28 · 76,045 certified options.
250 Series / Power Symphony Fixed
U-Factor 0.14–0.32 · 266 certified options.
250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement
U-Factor 0.15–0.32 · 144 certified options.
Architect Wood Fixed Casement
U-Factor 0.15–0.32 · 2,468 certified options.
Pella Entry Doors - Fiberglass Skin Door
U-Factor 0.15–0.28 · 242,982 certified options.
Pella Entry Doors - Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 319,127 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 appear below.
What thermal performance numbers separate Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 from peers?
Built with Other / Wood framing in Double-Hung (VSDH) style, Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 offers 168 Version 7.0 configurations from U 0.25 up to 0.32, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.
Can homeowners install Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 in cold Northern ENERGY STAR counties?
Northern qualification on Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.25. Exactly 4 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
What conductive BTU/hr difference separates Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 glazing packages pass Southern solar-heat rules?
Yes. 160 Southern-certified options inside Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 variants earn ENERGY STAR Most Efficient?
Zero glazing builds inside Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5's 168 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
What 2026 federal tax credit and Lead RRP rules apply to Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Pella Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 glass specs on job sites?
Verify NFRC ID PEL and series PEL-N-233 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)