Window · Wood Frame NFRC WEA · Product Line WEA-N-282

Weather Shield Mfg., Inc. — 8120/1104/1105 Double Hung · Double Hung

Positioning #1,174/1,352 in certified Window, Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung pairs Wood frame construction with 199 glazing options rated between 0.11 and 0.23 SHGC across North-Central, South-Central, Southern. Across 30 certified Weather Shield Mfg., Inc. product families, its thermal resistance spans 0.25 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.25
SHGC Range
0.11-0.23
Certified Options
199
Category Standing
#1,174 of 1,352

How does Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung compare thermally against Window peers?

Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8120/1104/1105 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 8120/1104/1105 Double Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8120/1104/1105 Double Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 8120/1104/1105 Double Hung spans 199 NFRC test records (WEA), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.04 against the Wood median (0.21).

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Data provenance links certification 2025-09-16 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 199 certified glazing combinations for 8120/1104/1105 Double Hung (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 10 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 51 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 199 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung appear below.

What U-Factor and SHGC range does Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung achieve?

Testing puts Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 199 configurations. Solar heat gain ranges between 0.11 and 0.23 across North-Central, South-Central, Southern.

Can homeowners install 8120/1104/1105 Double Hung in cold Northern ENERGY STAR counties?

Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung holds zero Northern Zone qualifications (min U 0.25). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How do you calculate winter heat conduction for Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on 8120/1104/1105 Double Hung's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Who should NOT choose Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung for a residential project?

Skip 8120/1104/1105 Double Hung if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8120/1104/1105 Double Hung options exceeding U 0.22.

Does 8120/1104/1105 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, 8120/1104/1105 Double Hung holds 199 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

Does 8120/1104/1105 Double Hung carry EPA Most Efficient certification across its lineup?

No. Zero of the 199 configurations in Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Can homeowners claim Form 5695 credits on Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 8120/1104/1105 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC WEA and product line WEA-N-282 on delivery?

Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.11-0.23) against permit drawings for line WEA-N-282. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8120/1104/1105 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros