Andersen Corporation — 400 Series Woodwright® Double-Hung Full-Frame Window · Double Hung
With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window spans 280 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.15 and 0.46.
- Min U-Factor
- 0.25
- SHGC Range
- 0.15-0.46
- Certified Options
- 280
- Category Standing
- #1,174 of 1,352
How does Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window compare thermally against Window peers?
Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window at rank #1,174 of 1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.15-0.46 band.
Mapping NFRC SHGC values (0.15 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 8 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2024-03-20.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 280 certified glazing combinations for 400 Series Woodwright® Double-Hung Full-Frame Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 8 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 40 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 76 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 256 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Kolbe and Kolbe Millwork Co., Inc — Ultra/VistaLuxe Exterior Folding Window | Wood | 0.25 | 0.08 | 271 |
| Weather Shield Mfg., Inc. — 8217 Push-Out Awning | Wood | 0.25 | 0.11 | 302 |
| Windsor Windows and Doors — Pinnacle Clad Awning 3.25" Frame | Wood | 0.25 | 0.15 | 354 |
| Weather Shield Mfg., Inc. — 8120/1104/1105 Double Hung | Wood | 0.25 | 0.11 | 199 |
| Windsor Windows and Doors — Pinnacle Clad Awning | Wood | 0.25 | 0.15 | 362 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window appear below.
What U-Factor and SHGC range does Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window achieve?
Built with Wood framing in Double-Hung (VSDH) style, Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window offers 280 Version 7.0 configurations from U 0.25 up to 0.32, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.
Does Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window qualify for the ENERGY STAR Northern Zone?
Prescriptive Northern approval ends at U <= 0.22, above 400 Series Woodwright® Double-Hung Full-Frame Window's 0.25 minimum. However, 8 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
What conductive BTU/hr difference separates 400 Series Woodwright® Double-Hung Full-Frame Window from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400 Series Woodwright® Double-Hung Full-Frame Window at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying 400 Series Woodwright® Double-Hung Full-Frame Window?
Do not specify 400 Series Woodwright® Double-Hung Full-Frame Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Woodwright® Double-Hung Full-Frame Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is 400 Series Woodwright® Double-Hung Full-Frame Window suitable for sunbelt cooling-dominated homes?
Yes. 256 Southern-certified options inside Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.
What glazing share inside 400 Series Woodwright® Double-Hung Full-Frame Window qualifies as Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 280 400 Series Woodwright® Double-Hung Full-Frame Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Do 2026 400 Series Woodwright® Double-Hung Full-Frame Window installations qualify for IRS Section 25C tax credits?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 400 Series Woodwright® Double-Hung Full-Frame Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
Where are NFRC and IGCC identification marks located on 400 Series Woodwright® Double-Hung Full-Frame Window?
Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.15-0.46) against permit drawings for line AND-N-66. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Woodwright® Double-Hung Full-Frame Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)