Skip to main content
Door · Wood Frame NFRC PEL · Product Line PEL-N-219

Pella Corporation — Pella Architect Wood Outswing Door · Swinging Entry Door (Single)

Across 39 Pella Corporation certified families, Pella Architect Wood Outswing Door supplies 1,150 Swinging Entry Door, Single configurations starting at 0.21 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.40 SHGC. Its thermal floor ranks #133 of 268 category entries—matches the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.09-0.40
Certified Options
1,150
Category Standing
#133 of 268

How does Pella Corporation Pella Architect Wood Outswing Door compare thermally against Door peers?

Pella Corporation Pella Architect Wood Outswing Door achieves a 0.21 thermal floor across Door lines, placing #133 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Pella Architect Wood Outswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Pella Architect Wood Outswing Door (U 0.21).28<=0.15650.16-0.18510.19-0.21This model: U 0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Pella Architect Wood Outswing Door Cohort StandingMin U-Factor 0.21 stands at rank #133 of 268, outperforming 46.3% of peers.Min U-Factor 0.21Rank #133 of 268 (46.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Pella Corporation Pella Architect Wood Outswing Door standing at #133 of 268 certified Door product series, tied with 11 others at 0.21, more insulating than 46.3% of Door lines. Comparing Wood profiles alone (median 0.21) shows At median before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 634 combinations qualify in the Northern Zone alongside 960 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.21 U-Factor yields 126.0 BTU/hr transfer (-6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2025-04-22 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,150 certified glazing combinations for Pella Architect Wood Outswing Door (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 634 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 634 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 960 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 960 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Wood Outswing Door appear below.

What U-Factor and SHGC range does Pella Corporation Pella Architect Wood Outswing Door achieve?

Across 1,150 tested NFRC glazing configurations, Pella Corporation Pella Architect Wood Outswing Door with Wood framing and Entry Door Single-Lite (EDSL) style reaches a 0.21 minimum U-Factor and 0.09-0.40 SHGC band. It places #133 among 268 Door series—more insulating than 46.3%.

How does Pella Corporation Pella Architect Wood Outswing Door satisfy Version 7.0 Northern criteria?

Yes. 634 packages in Pella Corporation Pella Architect Wood Outswing Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How much winter heat loss does Pella Architect Wood Outswing Door conduct across a 15 sq ft opening?

Using NFRC PEL U-Factor 0.21, a 15 sq ft Entry Door Single-Lite (EDSL) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).

What homeowner profiles are a poor match for Pella Corporation Pella Architect Wood Outswing Door?

Skip Pella Architect Wood Outswing Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Wood Outswing Door options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Pella Architect Wood Outswing Door?

Across Northern, North-Central, South-Central, Southern, 960 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Pella Corporation Pella Architect Wood Outswing Door, while total line SHGC reaches 0.40 in colder packages.

Which package tier in Pella Architect Wood Outswing Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 1,150 Pella Architect Wood Outswing Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 Pella Architect Wood Outswing Door window swaps?

Any Pella Architect Wood Outswing Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Pella Corporation Pella Architect Wood Outswing Door units match permits?

Verify NFRC ID PEL and series PEL-N-219 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Wood Outswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros