Skip to main content
Door · Vinyl Frame NFRC PGT · Product Line PGT-A-237

PGT Industries — SGD5470/5570 · Sliding Patio Door

Across 8 PGT Industries certified families, SGD5470/5570 supplies 6,114 Sliding Patio Door configurations starting at 0.27 U-Factor and 0.07 SHGC for South-Central, Southern, reaching up to 0.28 U-Factor and 0.23 SHGC. Its thermal floor ranks #249 of 268 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.27
SHGC Range
0.07-0.23
Certified Options
6,114
Category Standing
#249 of 268

How does PGT Industries SGD5470/5570 compare thermally against Door peers?

PGT Industries SGD5470/5570 achieves a 0.27 thermal floor across Door lines, placing #249 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. SGD5470/5570Histogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing SGD5470/5570 (U 0.27).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

SGD5470/5570 Cohort StandingMin U-Factor 0.27 stands at rank #249 of 268, outperforming 3.7% of peers.Min U-Factor 0.27Rank #249 of 268 (3.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places PGT Industries SGD5470/5570 at rank #249 of 268 (tied with 9 others at 0.27, more insulating than 3.7% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.07-0.23 band.

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.07 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-07-31.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,114 certified glazing combinations for SGD5470/5570 (NFRC PGT) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 6,114 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 6,114 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does PGT Industries produce?

Compare other active PGT Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to PGT Industries SGD5470/5570 appear below.

How efficient is PGT Industries SGD5470/5570 compared with peer Door models?

PGT Industries SGD5470/5570 spans 6,114 certified configurations with U-Factors between 0.27 and 0.28 and SHGC values from 0.07 to 0.23. Ranked #249 of 268 Door families, it carries 0 Most Efficient options.

Can homeowners install SGD5470/5570 in cold Northern ENERGY STAR counties?

PGT Industries SGD5470/5570 holds zero Northern Zone qualifications (min U 0.27). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

What conductive BTU/hr difference separates SGD5470/5570 from the 0.22 Northern rule?

At U 0.27, a standard 3x5 ft (15 sq ft) SGD5470/5570 opening transfers 162.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +30.0 BTU/hr difference.

When should a buyer skip PGT Industries SGD5470/5570 and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on SGD5470/5570 options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in SGD5470/5570?

Yes. 6,114 Southern-certified options inside PGT Industries SGD5470/5570 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does SGD5470/5570 carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 6,114 SGD5470/5570 options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to SGD5470/5570?

Any SGD5470/5570 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify SGD5470/5570 glass specs on job sites?

Match the NFRC thermal sticker for code PGT and line PGT-A-237 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for PGT Industries SGD5470/5570 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros