Ply Gem Window Group — Mira (2018) Awning · Awning (Projected)
With a minimum U-Factor of 0.20—At median compared against the 0.20 Window median—Ply Gem Window Group Mira (2018) Awning spans 14,440 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code PWG, the Wood assembly includes 543 ENERGY STAR Most Efficient packages (3.8% of line) and offers SHGC packages between 0.11 and 0.41.
- Min U-Factor
- 0.20
- SHGC Range
- 0.11-0.41
- Certified Options
- 14,440
- Category Standing
- #671 of 1,352
How does Ply Gem Window Group Mira (2018) Awning compare thermally against Window peers?
Ply Gem Window Group Mira (2018) Awning achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Mira (2018) Awning spans 14,440 NFRC test records (PWG), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at -0.01 against the Wood median (0.21).
Mapping NFRC SHGC values (0.11 to 0.41) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 543 configurations meet ENERGY STAR Most Efficient criteria while 479 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-08-23 and cert timestamp 2024-09-19.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 14,440 certified glazing combinations for Mira (2018) Awning (NFRC PWG) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 479 packages (7 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 2,436 packages (43 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 5,732 packages (42 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 13,896 packages (542 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Andersen Corporation — A-Series Awning Window | Wood | 0.20 | 0.10 | 7,291 |
| Andersen Corporation — E-Series Fixed Casement Window - Sash-Set (2 Piece) | Wood | 0.20 | 0.11 | 7,031 |
| Andersen Corporation — A-Series Casement Window | Wood | 0.20 | 0.10 | 6,963 |
| Andersen Corporation — A-Series Contemporary Casement Window | Wood | 0.20 | 0.10 | 6,698 |
| Marvin — Ultimate Double Hung / Single Hung Insert G2 | Wood | 0.20 | 0.11 | 2,595 |
What other certified series does Ply Gem Window Group produce?
Compare other active Ply Gem Window Group certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Mira (2018) Casement Stationary
U-Factor 0.17–0.32 · 14,893 certified options.
Ply Gem 1500 Brickmold Single Hung
U-Factor 0.17–0.32 · 220,958 certified options.
Pro Series Classic Sidelite/Transom
U-Factor 0.18–0.32 · 5,388 certified options.
Ply Gem 1500 Beveled Horizontal Slider
U-Factor 0.19–0.32 · 36,619 certified options.
Ply Gem 1500 Brickmold Horizontal Slider
U-Factor 0.19–0.32 · 35,135 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Ply Gem Window Group Mira (2018) Awning appear below.
Where does Ply Gem Window Group Mira (2018) Awning stand thermally among ENERGY STAR Window lines?
EPA ENERGY STAR v7.0 records 14,440 configurations for Ply Gem Window Group Mira (2018) Awning covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.20 Window median. Only 543 options earn Most Efficient status.
Does Ply Gem Window Group Mira (2018) Awning qualify for the ENERGY STAR Northern Zone?
Yes, 479 packages satisfy Northern ENERGY STAR Version 7.0 rules in Mira (2018) Awning. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How much winter heat loss does Mira (2018) Awning conduct across a 15 sq ft opening?
Using NFRC PWG U-Factor 0.20, a 15 sq ft Projected Awning (PRAW) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).
Which situations make Mira (2018) Awning the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Mira (2018) Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Does Mira (2018) Awning meet Southern hot-climate SHGC caps (<= 0.23)?
Across Northern, North-Central, South-Central, Southern, 13,896 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Ply Gem Window Group Mira (2018) Awning, while total line SHGC reaches 0.41 in colder packages.
What glazing share inside Mira (2018) Awning qualifies as Most Efficient?
Within Mira (2018) Awning, 3.8% (543 of 14,440) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
What federal compliance checks govern 2026 Mira (2018) Awning window swaps?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Ply Gem Window Group upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify Mira (2018) Awning glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.20-0.32, SHGC 0.11-0.41) against permit drawings for line PWG-M-178. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Ply Gem Window Group Mira (2018) Awning come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)