Skip to main content
Window · Wood Frame NFRC PWG · Product Line PWG-M-179 ENERGY STAR Most Efficient Eligible

Ply Gem Window Group — Mira (2018) Casement Stationary · Picture Window

Across 9 Ply Gem Window Group certified families, Mira (2018) Casement Stationary supplies 14,893 Picture Window configurations starting at 0.17 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.52 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.12-0.52
Certified Options
14,893
Category Standing
#362 of 1,352

How does Ply Gem Window Group Mira (2018) Casement Stationary compare thermally against Window peers?

Ply Gem Window Group Mira (2018) Casement Stationary achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Mira (2018) Casement StationaryHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Mira (2018) Casement Stationary (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Mira (2018) Casement Stationary Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Mira (2018) Casement Stationary is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Mapping NFRC SHGC values (0.12 to 0.52) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1,652 configurations meet ENERGY STAR Most Efficient criteria while 2,423 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-09-19 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 14,893 certified glazing combinations for Mira (2018) Casement Stationary (NFRC PWG) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 2,423 packages (444 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 6,421 packages (892 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 8,106 packages (689 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 11,570 packages (1,378 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Ply Gem Window Group produce?

Compare other active Ply Gem Window Group certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Ply Gem Window Group Mira (2018) Casement Stationary appear below.

Where does Ply Gem Window Group Mira (2018) Casement Stationary stand thermally among ENERGY STAR Window lines?

Ply Gem Window Group Mira (2018) Casement Stationary spans 14,893 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.12 to 0.52. Ranked #362 of 1,352 Window families, it carries 1,652 Most Efficient options.

Is Mira (2018) Casement Stationary approved for Northern Zone heating climates?

Yes. 2,423 packages in Ply Gem Window Group Mira (2018) Casement Stationary clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How much winter heat loss does Mira (2018) Casement Stationary conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Mira (2018) Casement Stationary at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Ply Gem Window Group Mira (2018) Casement Stationary for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Mira (2018) Casement Stationary options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Mira (2018) Casement Stationary?

Yes. 11,570 Southern-certified options inside Ply Gem Window Group Mira (2018) Casement Stationary satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.52 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in Mira (2018) Casement Stationary holds Most Efficient recognition?

Within Mira (2018) Casement Stationary, 11.1% (1,652 of 14,893) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Mira (2018) Casement Stationary?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Ply Gem Window Group upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Mira (2018) Casement Stationary after sticker removal?

Verify NFRC ID PWG and series PWG-M-179 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Ply Gem Window Group Mira (2018) Casement Stationary come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)