Andersen Corporation — 400 Series Specialty Window - Casement Half Circle · Picture Window
Andersen Corporation 400 Series Specialty Window - Casement Half Circle is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.17 across 5,280 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.15 to 0.52.
- Min U-Factor
- 0.17
- SHGC Range
- 0.15-0.52
- Certified Options
- 5,280
- Category Standing
- #362 of 1,352
How does Andersen Corporation 400 Series Specialty Window - Casement Half Circle compare thermally against Window peers?
Andersen Corporation 400 Series Specialty Window - Casement Half Circle achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 111 certified Andersen Corporation series, this Picture Window offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 528 configurations meet ENERGY STAR Most Efficient criteria while 1,346 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors AND to 2024-03-07 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 5,280 certified glazing combinations for 400 Series Specialty Window - Casement Half Circle (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 1,346 packages (84 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 2,164 packages (142 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 2,546 packages (78 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 3,888 packages (452 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Weather Shield Mfg., Inc. — 8312 Flush Frame Direct Set | Wood | 0.17 | 0.13 | 4,388 |
| Marvin — Ultimate Outswing French Door Transom G2 | Wood | 0.17 | 0.10 | 7,857 |
| Pella Corporation — Pella Architect Clad Fixed Casement | Wood | 0.17 | 0.11 | 2,200 |
| Pella Corporation — Pella Architect Wood Casement | Wood | 0.17 | 0.11 | 1,855 |
| Kolbe and Kolbe Millwork Co., Inc — Heritage Push Out Casement MPL & SPL | Wood | 0.17 | 0.08 | 1,730 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Specialty Window - Casement Half Circle appear below.
Where does Andersen Corporation 400 Series Specialty Window - Casement Half Circle stand thermally among ENERGY STAR Window lines?
Across 5,280 tested NFRC glazing configurations, Andersen Corporation 400 Series Specialty Window - Casement Half Circle with Wood framing and Fixed Window (FIXD) style reaches a 0.17 minimum U-Factor and 0.15-0.52 SHGC band. It places #362 among 1,352 Window series—top 35.2%.
Which glazing options in Andersen Corporation 400 Series Specialty Window - Casement Half Circle meet Northern climate limits?
Cold-climate buyers get 1,346 compliant Northern packages inside 400 Series Specialty Window - Casement Half Circle, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What BTU/hr heat transfer results from 400 Series Specialty Window - Casement Half Circle's 0.17 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400 Series Specialty Window - Casement Half Circle at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose Andersen Corporation 400 Series Specialty Window - Casement Half Circle for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Specialty Window - Casement Half Circle options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
What Southern ENERGY STAR v7.0 options exist in 400 Series Specialty Window - Casement Half Circle?
Exactly 3,888 400 Series Specialty Window - Casement Half Circle options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.52 glass.
How many Andersen Corporation 400 Series Specialty Window - Casement Half Circle variants earn ENERGY STAR Most Efficient?
Within 400 Series Specialty Window - Casement Half Circle, 10.0% (528 of 5,280) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
Can homeowners claim Form 5695 credits on Andersen Corporation 400 Series Specialty Window - Casement Half Circle in 2026?
Any 400 Series Specialty Window - Casement Half Circle purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How can homeowners confirm delivered Andersen Corporation 400 Series Specialty Window - Casement Half Circle units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-147 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Specialty Window - Casement Half Circle come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)