Skip to main content
Window · Wood Frame NFRC MAR · Product Line MAR-N-482 ENERGY STAR Most Efficient Eligible

Marvin — Ultimate Outswing French Door Transom G2 · Picture Window

Across 105 Marvin certified families, Ultimate Outswing French Door Transom G2 supplies 7,857 Picture Window configurations starting at 0.17 U-Factor and 0.10 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.41 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.10-0.41
Certified Options
7,857
Category Standing
#362 of 1,352

How does Marvin Ultimate Outswing French Door Transom G2 compare thermally against Window peers?

Marvin Ultimate Outswing French Door Transom G2 achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Outswing French Door Transom G2Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Ultimate Outswing French Door Transom G2 (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Outswing French Door Transom G2 Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultimate Outswing French Door Transom G2 spans 7,857 NFRC test records (MAR), ranking #362 of 1,352 Window families (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%). Its 0.17 thermal floor compares at -0.04 against the Wood median (0.21).

Mapping NFRC SHGC values (0.10 to 0.41) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 518 configurations meet ENERGY STAR Most Efficient criteria while 510 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors MAR to 2024-04-02 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,857 certified glazing combinations for Ultimate Outswing French Door Transom G2 (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 510 packages (194 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,382 packages (358 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,892 packages (238 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 7,347 packages (390 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Outswing French Door Transom G2 appear below.

How efficient is Marvin Ultimate Outswing French Door Transom G2 compared with peer Window models?

Across 7,857 tested NFRC glazing configurations, Marvin Ultimate Outswing French Door Transom G2 with Wood framing and Fixed Window (FIXD) style reaches a 0.17 minimum U-Factor and 0.10-0.41 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

Is Ultimate Outswing French Door Transom G2 approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 510 Ultimate Outswing French Door Transom G2 packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates Ultimate Outswing French Door Transom G2 from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying Ultimate Outswing French Door Transom G2?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Outswing French Door Transom G2 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in Ultimate Outswing French Door Transom G2?

Warm-climate homeowners have 7,347 Southern-approved options within Ultimate Outswing French Door Transom G2 spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 7,857 Ultimate Outswing French Door Transom G2 configurations ENERGY STAR Most Efficient?

Within Ultimate Outswing French Door Transom G2, 6.6% (518 of 7,857) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What federal compliance checks govern 2026 Ultimate Outswing French Door Transom G2 window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify Ultimate Outswing French Door Transom G2 glass specs on job sites?

Match the NFRC thermal sticker for code MAR and line MAR-N-482 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Outswing French Door Transom G2 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)