Skip to main content
Window · Wood Frame NFRC JEL · Product Line JEL-N-877 ENERGY STAR Most Efficient Eligible

JELD-WEN, inc. — Siteline Clad Wood (W-5500) Casement · Casement Windows

JELD-WEN, inc. engineered the Siteline Clad Wood (W-5500) Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 9,709 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.00 to 0.44 SHGC. Relative to other Wood models tracked under NFRC JEL, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.00-0.44
Certified Options
9,709
Category Standing
#362 of 1,352

How does JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement compare thermally against Window peers?

JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Siteline Clad Wood (W-5500) CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Siteline Clad Wood (W-5500) Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Siteline Clad Wood (W-5500) Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Siteline Clad Wood (W-5500) Casement is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 458 configurations meet ENERGY STAR Most Efficient criteria while 468 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-10-09.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 9,709 certified glazing combinations for Siteline Clad Wood (W-5500) Casement (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 468 packages (189 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,232 packages (327 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 4,722 packages (183 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 9,249 packages (314 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement appear below.

What thermal performance numbers separate JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement from peers?

JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement spans 9,709 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.00 to 0.44. Ranked #362 of 1,352 Window families, it carries 458 Most Efficient options.

Is Siteline Clad Wood (W-5500) Casement approved for Northern Zone heating climates?

JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement supplies 468 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How much winter heat loss does Siteline Clad Wood (W-5500) Casement conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying Siteline Clad Wood (W-5500) Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline Clad Wood (W-5500) Casement options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

How many Siteline Clad Wood (W-5500) Casement glazing packages pass Southern solar-heat rules?

Exactly 9,249 Siteline Clad Wood (W-5500) Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.00 rather than higher 0.44 glass.

How many JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 458 of 9,709 Siteline Clad Wood (W-5500) Casement glazing builds earn Most Efficient recognition (4.7%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 Siteline Clad Wood (W-5500) Casement window swaps?

Any Siteline Clad Wood (W-5500) Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify Siteline Clad Wood (W-5500) Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line JEL-N-877 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros