Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-86 ENERGY STAR Most Efficient Eligible

Andersen Corporation — A-Series Casement Window · Casement Windows

Andersen Corporation A-Series Casement Window is a Casement Windows assembly with a Wood frame that reaches a minimum U-Factor of 0.20 across 6,963 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #671 of 1,352 in Window, its thermal floor is matches the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.40.

Min U-Factor
0.20
SHGC Range
0.10-0.40
Certified Options
6,963
Category Standing
#671 of 1,352

How does Andersen Corporation A-Series Casement Window compare thermally against Window peers?

Andersen Corporation A-Series Casement Window achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A-Series Casement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing A-Series Casement Window (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A-Series Casement Window Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), A-Series Casement Window is matches the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.20-0.32.

Mapping NFRC SHGC values (0.10 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 67 configurations meet ENERGY STAR Most Efficient criteria while 53 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,963 certified glazing combinations for A-Series Casement Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 53 packages (8 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 657 packages (21 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,972 packages (17 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 6,805 packages (63 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Casement Window appear below.

What thermal performance numbers separate Andersen Corporation A-Series Casement Window from peers?

Andersen Corporation A-Series Casement Window spans 6,963 certified configurations with U-Factors between 0.20 and 0.32 and SHGC values from 0.10 to 0.40. Ranked #671 of 1,352 Window families, it carries 67 Most Efficient options.

Which glazing options in Andersen Corporation A-Series Casement Window meet Northern climate limits?

Cold-climate buyers get 53 compliant Northern packages inside A-Series Casement Window, reaching down to U 0.20. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates A-Series Casement Window from the 0.22 Northern rule?

At U 0.20, a standard 3x5 ft (15 sq ft) A-Series Casement Window opening transfers 120.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -12.0 BTU/hr difference.

What homeowner profiles are a poor match for Andersen Corporation A-Series Casement Window?

Skip A-Series Casement Window if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Casement Window options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in A-Series Casement Window?

Warm-climate homeowners have 6,805 Southern-approved options within A-Series Casement Window spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does A-Series Casement Window carry EPA Most Efficient certification across its lineup?

Only 67 options out of 6,963 (1.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Andersen Corporation A-Series Casement Window, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on Andersen Corporation A-Series Casement Window in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC AND and product line AND-N-86 on delivery?

Inspectors match the temporary NFRC sticker (U 0.20-0.32, SHGC 0.10-0.40) against permit drawings for line AND-N-86. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Casement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros