Ply Gem Window Group — Mira (2018) Casement · Casement Windows
Ply Gem Window Group Mira (2018) Casement is a Casement Windows assembly with a Wood frame that reaches a minimum U-Factor of 0.20 across 14,863 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #671 of 1,352 in Window, its thermal floor is matches the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.44.
- Min U-Factor
- 0.20
- SHGC Range
- 0.11-0.44
- Certified Options
- 14,863
- Category Standing
- #671 of 1,352
How does Ply Gem Window Group Mira (2018) Casement compare thermally against Window peers?
Ply Gem Window Group Mira (2018) Casement achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 9 certified Ply Gem Window Group series, this Casement Windows offers a 0.12 U-Factor adjustment span between 0.32 entry options and 0.20 top-performing glazing. Category standing is #671/1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines).
Mapping NFRC SHGC values (0.11 to 0.44) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 554 configurations meet ENERGY STAR Most Efficient criteria while 507 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2025-01-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.20 conducts 120.0 BTU/hr (-12.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 14,863 certified glazing combinations for Mira (2018) Casement (NFRC PWG) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 507 packages (12 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 2,734 packages (47 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 6,672 packages (43 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 14,247 packages (550 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Andersen Corporation — A-Series Awning Window | Wood | 0.20 | 0.10 | 7,291 |
| Andersen Corporation — E-Series Fixed Casement Window - Sash-Set (2 Piece) | Wood | 0.20 | 0.11 | 7,031 |
| Andersen Corporation — A-Series Casement Window | Wood | 0.20 | 0.10 | 6,963 |
| Andersen Corporation — A-Series Contemporary Casement Window | Wood | 0.20 | 0.10 | 6,698 |
| Marvin — Ultimate Double Hung / Single Hung Insert G2 | Wood | 0.20 | 0.11 | 2,595 |
What other certified series does Ply Gem Window Group produce?
Compare other active Ply Gem Window Group certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Mira (2018) Casement Stationary
U-Factor 0.17–0.32 · 14,893 certified options.
Ply Gem 1500 Brickmold Single Hung
U-Factor 0.17–0.32 · 220,958 certified options.
Pro Series Classic Sidelite/Transom
U-Factor 0.18–0.32 · 5,388 certified options.
Ply Gem 1500 Beveled Horizontal Slider
U-Factor 0.19–0.32 · 36,619 certified options.
Ply Gem 1500 Brickmold Horizontal Slider
U-Factor 0.19–0.32 · 35,135 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Ply Gem Window Group Mira (2018) Casement appear below.
How well does Mira (2018) Casement by Ply Gem Window Group insulate relative to Window benchmarks?
Across 14,863 tested NFRC glazing configurations, Ply Gem Window Group Mira (2018) Casement with Wood framing and Casement Single-Vent (CSSV) style reaches a 0.20 minimum U-Factor and 0.11-0.44 SHGC band. It places #671 among 1,352 Window series—more insulating than 45.2%.
Can homeowners install Mira (2018) Casement in cold Northern ENERGY STAR counties?
Yes, 507 packages satisfy Northern ENERGY STAR Version 7.0 rules in Mira (2018) Casement. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
What conductive BTU/hr difference separates Mira (2018) Casement from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Mira (2018) Casement at U 0.20 conducts 120.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying Mira (2018) Casement?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Mira (2018) Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
What Southern ENERGY STAR v7.0 options exist in Mira (2018) Casement?
Yes. 14,247 Southern-certified options inside Ply Gem Window Group Mira (2018) Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.44 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many Ply Gem Window Group Mira (2018) Casement variants earn ENERGY STAR Most Efficient?
Not every package qualifies: 554 of 14,863 Mira (2018) Casement glazing builds earn Most Efficient recognition (3.7%), while other variants sit on the standard Version 7.0 tier.
What federal compliance checks govern 2026 Mira (2018) Casement window swaps?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Mira (2018) Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on Mira (2018) Casement?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code PWG and product line PWG-M-177, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Ply Gem Window Group Mira (2018) Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)