Skip to main content
Door · Steel / Vinyl / Wood Frame NFRC PRD · Product Line PRD-N-86

ProVia LLC — 20 Gauge Steel Entry Door · Swinging Entry Door (Single)

ProVia LLC engineered the 20 Gauge Steel Entry Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 3,892 glass-spacer combinations from 0.17 to 0.28 U-Factor and 0.01 to 0.23 SHGC. Relative to other Steel / Vinyl / Wood models tracked under NFRC PRD, its minimum U-Factor is 0.04 Btu/hr·ft²·°F less insulating than the 0.13 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.01-0.23
Certified Options
3,892
Category Standing
#55 of 268

How does ProVia LLC 20 Gauge Steel Entry Door compare thermally against Door peers?

ProVia LLC 20 Gauge Steel Entry Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 20 Gauge Steel Entry DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 20 Gauge Steel Entry Door (U 0.17).28<=0.15650.16-0.18This model: U 0.17510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

20 Gauge Steel Entry Door Cohort StandingMin U-Factor 0.17 stands at rank #55 of 268, outperforming 72.4% of peers.Min U-Factor 0.17Rank #55 of 268 (72.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), 20 Gauge Steel Entry Door is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Steel / Vinyl / Wood frame with Steel sash. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.28.

Mapping NFRC SHGC values (0.01 to 0.23) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 3,164 combinations qualify in the Northern Zone alongside 3,892 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2023-11-14.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,892 certified glazing combinations for 20 Gauge Steel Entry Door (NFRC PRD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 3,164 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 3,164 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 3,892 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,892 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does ProVia LLC produce?

Compare other active ProVia LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ProVia LLC 20 Gauge Steel Entry Door appear below.

What U-Factor and SHGC range does ProVia LLC 20 Gauge Steel Entry Door achieve?

ProVia LLC 20 Gauge Steel Entry Door spans 3,892 certified configurations with U-Factors between 0.17 and 0.28 and SHGC values from 0.01 to 0.23. Ranked #55 of 268 Door families, it carries 0 Most Efficient options.

Which glazing options in ProVia LLC 20 Gauge Steel Entry Door meet Northern climate limits?

Yes, 3,164 packages satisfy Northern ENERGY STAR Version 7.0 rules in 20 Gauge Steel Entry Door. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does 20 Gauge Steel Entry Door conduct across a 15 sq ft opening?

At U 0.17, a standard 3x5 ft (15 sq ft) 20 Gauge Steel Entry Door opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

Which situations make 20 Gauge Steel Entry Door the wrong window or door choice?

Skip 20 Gauge Steel Entry Door if local historic preservation boards prohibit Steel / Vinyl / Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 20 Gauge Steel Entry Door options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in 20 Gauge Steel Entry Door?

Exactly 3,892 20 Gauge Steel Entry Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.01 rather than higher 0.23 glass.

What glazing share inside 20 Gauge Steel Entry Door qualifies as Most Efficient?

All 3,892 20 Gauge Steel Entry Door listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 20 Gauge Steel Entry Door window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 20 Gauge Steel Entry Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC PRD and product line PRD-N-86 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code PRD and product line PRD-N-86, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ProVia LLC 20 Gauge Steel Entry Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros