Skip to main content
Door · Wood Frame NFRC SIE · Product Line SIE-N-28

Sierra Pacific Windows — Aluminum Clad Outswing/Sidelite · Swinging Entry Door (Single)

With a minimum U-Factor of 0.25—+0.04 compared against the 0.21 Door median—Sierra Pacific Windows Aluminum Clad Outswing/Sidelite spans 364 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code SIE, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.08 and 0.33.

Min U-Factor
0.25
SHGC Range
0.08-0.33
Certified Options
364
Category Standing
#216 of 268

How does Sierra Pacific Windows Aluminum Clad Outswing/Sidelite compare thermally against Door peers?

Sierra Pacific Windows Aluminum Clad Outswing/Sidelite achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Aluminum Clad Outswing/SideliteHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Aluminum Clad Outswing/Sidelite (U 0.25).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.25100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Aluminum Clad Outswing/Sidelite Cohort StandingMin U-Factor 0.25 stands at rank #216 of 268, outperforming 13.4% of peers.Min U-Factor 0.25Rank #216 of 268 (13.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Sierra Pacific Windows Aluminum Clad Outswing/Sidelite at rank #216 of 268 (tied with 16 others at 0.25, more insulating than 13.4% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.08-0.33 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 65 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-27.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 364 certified glazing combinations for Aluminum Clad Outswing/Sidelite (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 65 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 65 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 353 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 353 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Elevate Outswing French Door G3 Wood 0.25 0.14 204
Marvin — Infinity Outswing French Door Wood 0.25 0.14 144
Quaker Window Products — W200 Sliding Glass Door Wood 0.25 0.16 135
Marvin — Elevate Outswing French Door Wood 0.25 0.14 130
Windsor Windows and Doors — Pinnacle Primed Inswing Door Fixed Wood 0.25 0.14 91

What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Aluminum Clad Outswing/Sidelite appear below.

Where does Sierra Pacific Windows Aluminum Clad Outswing/Sidelite stand thermally among ENERGY STAR Door lines?

EPA ENERGY STAR v7.0 records 364 configurations for Sierra Pacific Windows Aluminum Clad Outswing/Sidelite covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Is Aluminum Clad Outswing/Sidelite approved for Northern Zone heating climates?

Prescriptive Northern approval ends at U <= 0.22, above Aluminum Clad Outswing/Sidelite's 0.25 minimum. However, 65 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How much winter heat loss does Aluminum Clad Outswing/Sidelite conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.25 U-Factor yields 150.0 BTU/hr conductive transfer (+13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Sierra Pacific Windows Aluminum Clad Outswing/Sidelite for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Aluminum Clad Outswing/Sidelite options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does Aluminum Clad Outswing/Sidelite meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 353 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Sierra Pacific Windows Aluminum Clad Outswing/Sidelite, while total line SHGC reaches 0.33 in colder packages.

Does Aluminum Clad Outswing/Sidelite carry EPA Most Efficient certification across its lineup?

Aluminum Clad Outswing/Sidelite holds zero Most Efficient entries across its 364 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on Sierra Pacific Windows Aluminum Clad Outswing/Sidelite in 2026?

Any Aluminum Clad Outswing/Sidelite purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify Aluminum Clad Outswing/Sidelite glass specs on job sites?

Verify NFRC ID SIE and series SIE-N-28 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Aluminum Clad Outswing/Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)