Skip to main content
Door · Wood Frame NFRC WIN · Product Line WIN-N-141

Windsor Windows and Doors — Pinnacle Primed Inswing Door Fixed · Swinging Entry Door (Single)

Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed is a Swinging Entry Door, Single assembly with a Wood frame that reaches a minimum U-Factor of 0.25 across 91 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #216 of 268 in Door, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.39.

Min U-Factor
0.25
SHGC Range
0.14-0.39
Certified Options
91
Category Standing
#216 of 268

How does Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed compare thermally against Door peers?

Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Pinnacle Primed Inswing Door FixedHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Pinnacle Primed Inswing Door Fixed (U 0.25).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.25100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Pinnacle Primed Inswing Door Fixed Cohort StandingMin U-Factor 0.25 stands at rank #216 of 268, outperforming 13.4% of peers.Min U-Factor 0.25Rank #216 of 268 (13.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Pinnacle Primed Inswing Door Fixed is 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.25-0.28.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 30 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-17. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 91 certified glazing combinations for Pinnacle Primed Inswing Door Fixed (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 30 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 30 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 81 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 81 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Sierra Pacific Windows — Aluminum Clad Slider Wood 0.25 0.10 95
JELD-WEN, inc. — Custom Clad Sliding Door Wood 0.25 0.15 67
Weather Shield Mfg., Inc. — 8611/1606 Outswing Door Wood 0.25 0.11 56
Marvin — Elevate Outswing French Door Wood 0.25 0.14 130
Quaker Window Products — W200 Sliding Glass Door Wood 0.25 0.16 135

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed appear below.

Where does Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed stand thermally among ENERGY STAR Door lines?

EPA ENERGY STAR v7.0 records 91 configurations for Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Which glazing options in Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above Pinnacle Primed Inswing Door Fixed's 0.25 minimum. However, 30 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How do you calculate winter heat conduction for Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Pinnacle Primed Inswing Door Fixed's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

Which situations make Pinnacle Primed Inswing Door Fixed the wrong window or door choice?

Do not specify Pinnacle Primed Inswing Door Fixed without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Primed Inswing Door Fixed options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in Pinnacle Primed Inswing Door Fixed?

Warm-climate homeowners have 81 Southern-approved options within Pinnacle Primed Inswing Door Fixed spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 91 Pinnacle Primed Inswing Door Fixed configurations ENERGY STAR Most Efficient?

No. Zero of the 91 configurations in Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to Pinnacle Primed Inswing Door Fixed?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Pinnacle Primed Inswing Door Fixed retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC WIN and product line WIN-N-141 on delivery?

Inspectors match the temporary NFRC sticker (U 0.25-0.28, SHGC 0.14-0.39) against permit drawings for line WIN-N-141. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Primed Inswing Door Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)